Procedure
1. Make sure that the basin is empty / the
condensate water has been pumped
out .
2. Make sure that the discharge hose
(optional) and the mains cable have
been disconnected from the appliance.
3. Release the brakes on the castors.
4. Transport the dehumidifier to where it
is going to be used.
Heavy appliances that do not have
castors/wheels should be carried by
two people.
5. Lock the brakes on the castors to se-
cure the appliance.
NOTE: The air must circulate freely. Do
not cover the air openings. There must be
a clearance of at least 1 m in front of the
air outlet and the air filter.
Preparing the basin
Does not apply to the AD 810 or if an
optional discharge hose is connected.
Procedure
Slide the basin into the dehumidifier.
: Connecting the discharge hose
With the AD 810 it is essential to connect
the discharge hose provided.
Important! Inadequate appliance out-
put!
 Do not bend the discharge hose.
 Do not place any objects on the hose.
Procedure
1. Attach the quick connector to the dis-
charge hose and secure using the
hose clamp.
2. Attach the discharge hose provided to
the back of the appliance at the con-
nection nozzle.
3. Run the discharge hose away from the
dehumidifier to a drain or into a suita-
ble container (maximum height differ-
ence: 4 m).
Connecting an optional discharge
hose
If necessary, with all appliances (except
for AD 810) the condensate water can be
drained off via a discharge hose instead of
into the basin. To do this, proceed as
follows:
Important! Inadequate appliance out-
put!
 Do not place the end of the hose in the
water (backwater possible).
 Do not bend the discharge hose.
 Do not place any objects on the hose.
Procedure
1. Remove the basin.
2. Attach a suitable hose (12 x 2 mm) to
the discharge nozzle using a pipe clip.
3. Make sure that the end of the hose is
lower than the start of the hose at the
discharge nozzle. Minimum slope of
5% (5 cm/metre).
4. Slide the top cover sheet in front of the
notch. To do this, loosen the screw on
the cover sheet and slide the cover
sheet to the left.