Télécharger Imprimer la page

Sanisan 1 Mode D'emploi page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
8
NORM
• SANISAN
conforms to EN 12050-3.
®
Lifting plant for wastewater containing faecal matter for
limited applications.
9
COMMISSIONING THE UNIT
Once electrical and plumbing connections have been made,
flush the toilet once. The motor should run from 10 to 30
seconds to clear the waste (depending on the length and
height of the pipe run). If it runs for more than 35 seconds,
check that the pipework is clear, and that the discharge
hose is not kinded, or that the non-return valve is correctly
installed.
Also check that all seals, and connections are watertight.
Check both the discharge pipework from the unit, and the
waste pipes from washbasin.
or shower.
WARNING:
Any leaks from faucets or toilet will cause the
unit to activate repeatedly as it will fill up the case and
eventually will pump pumps the water away.
1 0
USAGE
The system does not require any special maintenance.
The SANISAN
will operate automatically as soon as the
®
required level of water enters the case.
WARNING:
The SANISAN
the evacuating of normal human waste, toilet paper and
household toilet bowl cleaners.
Damage may occur to the machine if the following are
disposed of via the toilet; Cotton wool, dental floss,
tampons, sanitary napkins, wet wipes, kitchen towels,
condom as well as other fabric or hard objects.
Solvents, acids and other chemicals can olso also
cause damage to the unit, and will invalidate the
warranty.
1 0
CARE OF YOUR SANISAN
• Normal household bleaches toilet bowl cleaners can be
used with a SANISAN
®
• To avoid the build up of limescale in the unit, use the
following procedure.
- disconnect the power supply to the unit,
- pour 3 or 4 litres of water mixed with a strong solution
of descalent into the toilet bowl,
- leave it to stand for 1 or 2 hours, then re-connect the
electric supply,
- flush several times to clear.
The frequency of this operation will depend on the
hardness of the water in your locality. We would
recommend this be done about twice a year.
®
range should only be used for
®
UNIT
.
1 2
FAULT FINDING/REMEDIES
For the most part any inconsistencies in the operation of the
unit will be minor and easily rectified. Please refer to the chart
below. If the problem cannot be easily remedied in this way.
Please call our Service organisation.
Warning - Always disconnect the electricity supply before
attempting any work on the SANISAN
SYMPTOM
PROBABLE CAUSES
• The motor
• The toilet tank or taps
intermittently activates
are dripping
• The external non-return
valve D is faulty
• The water in the toilet
• The inner grille is
goes down very slowly
clogged up
• The motor operates
• The length or height of
normally, but continues
the installation is over
to run for a long time
the specification, or
there are too many
bends/elbows
• The pump itself is
blocked
• The activating pressure
membrane is distorted
• The motor does not
• The electrical supply is
activate
not active
• The motor is defective
• The motor omits a
• A foreign object has
rattling or crunching
entered into the grille
sound
via the bowl
• The motor hums, but
• The capacitor or motor
does not run
is defective
1 3
REMOVAL OF SYSTEM
Any replacement of the power supply cable should only be
carried out by an authorised SANISAN service engineer.
1. Turn off the water supply to the toilet. If still working flush the
toilet). If not, bail out as much water as possible from the tank
and bowl.
2. Disconnect the electrical power supply.
3. Remove the toilet from the Sanisan.
4. Disconnect the discharge pipes.
a. Disconnect the inlet connections.
b. Beware of residual water in drain pipes.
5. Remove the 2 screws, which secures the Sanisan on the ground.
5. Remove the motor from the case
a. Remove the lid (using a torx T20 screwdriver).
b. Remove the 2 screws, which secures the motor to the case.
c. Loosen the cable clip.
d. Lift the motor out of the case.
NOTE:
For easy replacement of the lid, lubricate the lid seal with liquid
soap.
Do not reconnect the electrical power supply until
the re-installation is complete.
1 4
WARRANTY
The SANISAN
®
is guaranteed for one-year from the date
of purchase, subject to correct installation and usage.
.
®
REMEDIES
• Check the appropriate
washers/seals on the
cistern/taps etc
• Clean or replace the
non-return valve
• Clear the grille
• Check the installation
• Unblock the unit
• Replace the membrane
• Restore the electrical
supply
• Inspect the motor
• Remove the foreign
object from the unit
• Inspect the motor

Publicité