Specification

17.3 DHW output

The DHW output is subject to the connected power supply, the
appliance's connected load and the cold water inlet temperature.
The rated voltage and rated output can be found on the type plate.
Connected load in kW
38 °C DHW output in l/min.
Rated voltage
Cold water inlet temperature
220 V
230 V
240 V
6.0
8.0
6.6
8.7
7.2
9.6
10.0
12.0
11.0
13.1
12.0
14.3
Connected load in kW
50 °C DHW output in l/min.
Rated voltage
Cold water inlet temperature
220 V
230 V
240 V
6.0
8.0
6.6
8.7
7.2
9.6
10.0
12.0
11.0
13.1
12.0
14.3
17.4 Application areas / conversion table
Electrical resistivity and electrical conductivity.
Standard specifica-
tion at 15 °C
20 °C
Conductivity σ ≤ Resis-
Resis-
tivity
tivity
ρ ≥
ρ ≥
Ωcm
mS/m μS/cm
Ωcm
1100
91
910
970

17.5 Pressure drop

Taps
Tap pressure drop at a flow rate of 10 l/min
Mono lever mixer tap, approx.
Thermostatic valve, approx.
Shower head, approx.
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1 MPa is recommended.
www.stiebel-eltron.com
5 °C
10 °C
15 °C
2.6
3.1
3.7
3.5
4.1
5.0
2.9
3.4
4.1
3.8
4.4
5.4
3.1
3.7
4.5
4.2
4.9
6.0
4.3
5.1
6.2
5.2
6.1
7.5
4.8
5.6
6.8
5.7
6.7
8.1
5.2
6.1
7.5
6.2
7.3
8.9
5 °C
10 °C
15 °C
1.9
2.1
2.4
2.5
2.9
3.3
2.1
2.4
2.7
2.8
3.1
3.6
2.3
2.6
2.9
3.0
3.4
3.9
3.2
3.6
4.1
3.8
4.3
4.9
3.5
3.9
4.5
4.2
4.7
5.3
3.8
4.3
4.9
4.5
5.1
5.8
25 °C
Conductivity σ ≤ Resis-
Conductivity σ ≤
tivity
ρ ≥
mS/m μS/cm
Ωcm
mS/m
103
1031
895
112
MPa
0.04 - 0.08
MPa
0.03 - 0.05
MPa
0.03 - 0.15
17.6 Fault conditions
In the event of a fault, loads up to 80 °C at a pressure of 1.0 MPa
can occur briefly in the installation.

17.7 Energy consumption data

Product datasheet: Conventional water heaters to regulation (EU)
20 °C
no. 812/2013 | 814/2013
4.8
6.3
5.2
6.9
Manufacturer
5.7
Load profile
7.6
Energy efficiency class
7.9
Energy conversion efficiency
9.5
Annual power consumption
8.7
Default temperature setting
10.4
Sound power level
9.5
Special information on measuring
11.3
efficiency
20 °C
Daily power consumption
2.9
3.8
3.1
4.1
3.4
4.6
4.8
5.7
5.2
6.2
5.7
6.8
μS/cm
1117
DCE-X 6/8
DCE-X 10/12
Premium
Premium
238158
238159
STIEBEL ELTRON STIEBEL ELTRON
XS
A
%
39
kWh
472
°C
60
dB(A)
15
Measured at
Measured at
ECO level with
ECO level with
highest flow
highest flow
rate, maximum
rate, maximum
output and max-
output and max-
imum set value.
imum set value.
kWh
2.161
DCE-X Premium |
XS
A
39
473
60
15
2.167
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dce-x 10/12 premium