EIBENSTOCK EHR 15.2 SB Notice Originale page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Electrical Connection
Before starting the machine check the correspondence between voltage and
frequency against the data mentioned on the identification plate. Voltage
differences from + 6 % and – 10 % are allowed.
The mixing machine is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section
which is too small could lead to an excessive power loss and to overheating
of motor and cable.
Tool Change
Attention!
Before any work on the tool, disconnect the plug from the mains!
When inserting the tool, you could catch your hands. For this reason,
always wear protective gloves for changing the tool.
The work spindle of the machine has an M 14 - internal thread. Keep threads
and front surface clean.
Please hold up with a jaw wrench 22 to remove the stirring rod.
Tool Protection
A wrong handling can result in damages.
Hence, the following instructions should be observed:
Use only paddles recommended from the producer with M 14 – internal
thread (diameter max. 120 mm).
Do not allow blocking of the tool due to overload.
Use only original parts from EIBENSTOCK.
Switching on and off
Short-Time Operation
Switching-on:
press the on/off switch
Switching-off:
release the on/off switch
Permanent Operation
Switching-on:
press the on/off switch and, keeping it pressed, engage the
lock button
Switching-off:
press the on/off switch and let it go off again