Flow Diagram - Hansgrohe AXOR Starck 10006000 Mode D'emploi / Instructions De Montage

Masquer les pouces Voir aussi pour AXOR Starck 10006000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages.
• After it has been installed, no transport or surface
damage will be honoured.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
4
English
®
(flow
®
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 34)

Flow diagram

(see page 35)
with EcoSmart
without EcoSmart
Operation (see page 35)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning
see enclosed brochure.
Spare parts (see page 36)
Special accessories
special tool (58085000) order as an extra
Installation putty order as an extra
Test certificate (see page 33)
®
®

Publicité

Table des Matières
loading

Table des Matières