Whirlpool W11389806B Guide D'utilisation page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.
Connect neutral wire
C
Place hooked end of neutral wire (white or center) (C) of direct
wire cable under center screw of terminal block (B), hook facing
right. Squeeze hooked end together. Tighten screw.
3.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together, tighten screws, tighten strain
relief screws. Finally, replace the terminal block cover and
secure with the 4 hold-down screws. Now, go to "Level Dryer."
Optional External Ground for 3-Wire
Connection
(Power Supply Cord Shown)
IMPORTANT: You must verify with a qualified electrician
that this grounding method is acceptable before connecting.
1.
Prepare to connect neutral wire
D
Remove center terminal block screw (B) and green external
ground conductor screw (A). Loop neutral bonding wire (blue)
(D) to center terminal block location.
2.
B
D
Connect neutral wire (white or center) (C) of power supply cord
or cable under center terminal block screw (B). Make sure
the end of neutral bonding wire (white) (D) looped in Step 1
remains on the center terminal when the power supply cord
neutral wire is attached. Tighten screw.
3.
Place ends of remaining wires under outer terminal block
screws. Tighten screws and tighten strain relief.
4.
B
A
Connect a separate copper ground wire (G) under the green
external ground conductor screw (A) to an adequate ground.
Finally, replace the terminal block cover and secure with the 4
hold-down screws. Now, go to "Level Dryer."
Connect neutral wire
B
D
C
Connect remaining wires
Connect external ground wire
G
A
23