BFT BOTTICELLI SMART BT A 850 Instructions D'assemblage Et D'utilisation page 24

Masquer les pouces Voir aussi pour BOTTICELLI SMART BT A 850:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Logic
Definition
HOLD-TO-RUN
Deadman
Block pulses
IBL OPEN
during opening
Configuration
of safety input
SAFE 1
SAFE 1.
72
Configuration
of safety input
SAFE 2
SAFE 2.
73
Configuration of
command input
IC 1
IC 1.
61
Configuration of
command input
IC 2
IC 2.
62
Configuration
of the 1st radio
1ch
channel com-
mand
Configuration
of the 2nd radio
2ch
channel com-
mand
Configuration
of the 3rd radio
3 ch
channel com-
mand
Configuration
of the 4th radio
4 ch
channel com-
mand
Configuration of
AUX 3 output.
AUX 3
26-37
24
BOTTICELLI SMART BT A 850-1250
ENGLISH
Cross
out
Default
setting
used
Only active on FW ≥ 1.03
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman mode is ena-
bled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
0
2
Input 61 is configured as OPEN
Input 62 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Dead-man function during closing.
The input 61 is configured as OPEN UP.
The input 62 is configured as CLOSE UP.
3
The opening manoeuvre occurs automatically, the closing manoeuvre continues until the control button (CLOSE) is pressed.
WARNING: safety devices are not active during the opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
6
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2. (Inactive on SAFE 2).
9
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing, the
10
movement stops.
4
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the movement
11
stops. (Inactive on SAFE 2).
12
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening, the
13
movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the movement
14
stops. (Inactive on SAFE 2).
15
Not used
16
Input configured as STAR 8k2. (Inactive on SAFE 2).
0
Input configured as Start E.
1
Input configured as Start I.
0
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
4
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
0
Radio control configured as START E.
0
1
Radio control configured as Start I.
2
Radio control configured as Open.
3
Radio control configured as Close
12
4
Radio control configured as Ped
5
Radio control configured as STOP
6
Not used
9
7
Not used
8
Not used
9
Radio control configured as AUX3 **
10
Radio control configured as EXPO1 **
4
11
Radio control configured as EXPO2 **
12
Radio control configured as COURTESY LIGHT
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Not used
4
Not used
Output not configured as alarm (Fig. T). In auto mode, the T4 of the stored transmitter becomes the alarm activa-
5
tor/de-activator.
6
Not used
7
Not used
0
8
Not used
9
Output configured as Maintenance
10
Not used
11
Not used
12
Not used
13
Output configured as closed Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
16
Output configured as open Gate Status
Optional extras
UP.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Botticelli smart bt a 1250

Table des Matières