General Instructions; Preparation; The Chimney Ue - WANDERS Oak Série Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Oak side panels and feet are manufactured products consisting of various materials further re ned and colored
subsequently. Wanders do not guarantee any di erences in tones and shades of coloring and cannot be held
accountable, if there are any.
Any complaints will be dealt with after the sales rm, the installer has led a complaint and sent a copy of the
purchase receipt with purchase date. Any repairs do not entitle you to extend the guarantee term. All consequential
damages or loss are excluded.

General instructions

The Oak is tested in accordance with the international EN 13240 standardization, and has an extra additional
standardization for optimally environment-friendly heating devices related to ue gases. The stove can be
connected to a ue tube to which several stoves are connected. The ue tube has a diameter of 150 millimetres.
The heating device must be placed by an acknowledged installer and according to the installation instructions
given below. The national and local rules and regulations for placing and using wood-burning stoves are equally
applicable. WANDERS does not give any guarantee if the Oak is connected or installed incompletely or incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2 dwellings.
Spaces where highly ammable or explosive materials are used.
Spaces where an exhaust system is used or where a mechanical exhaust system is placed, except when the air
supply is taken directly from outside to assure a hazardless combustion.

Preparation

The chimney ue

Before placing the stove you must observe the following points:
If the stove is connected to an existing chimney, you must rst have the chimney professionally cleaned and
checked by a quali ed chimney sweep company. Any cut-o valves or stop valves must be removed.
The ue tube of the stove must be connected with the chimney without diversions.
The underpressure in the chimney must be at least 12 Pa or 0.12 mbar.
The chimney ue must always end up in outlet area 1 (see drawing below)
At the time of placing the stove, the chimney
ue must be clean, leak-proof and without
obstructions, and must have a diameter of
150 mm.
Any bends in the ue tube must not exceed
45 degrees.
Ensure that the chimney tube can discharge
the
ue gases adequately, properly and
safely.
The values for calculating the chimney
tube is given in the section on Technical
Information, page 26.