OIL MIST
ADJUSTMENT
STEP 6)
The proper amount of oil mist has already been factory preset. However, depending on the viscosity of
the oil being used, slight adjustments may be necessary. With the blower running, the proper oil mist
should be one drop/min. The oil mist adjustment screw is located next to the oil fill cap. Turn this
screw clockwise to decrease or counterclockwise to increase oil flow. Note: Approximately 1 drop
OIL DROP
per minute can be achieved by turning the adjustment screw fully clockwise and then turn
SIGHT GLASS
counterclockwise 1 1/2 turns.
SHUTDOWN
Insure that all workers are removed from the confined space site.
Shut off blower and remove all ducting.
MAINTENANCE
Keep blower motor dry and free from contaminants and dust.
Check periodically to ensure moving parts are free from obstructions.
Change filter (Part# WL040B) located in regulator after approximately 300 - 500 hours
Use SAE #10 automotive engine oil or lighter in lubricator at all times. (Do not exceed 10 weight oil). Heavy
weight oils will cause damage to the air motor.
Clean muffler assembly every 100-300 hours with safety solvent (Part #BAC-1001).
Flush air motor every 100 hours with safety solvent (#BAC-1001) through maintenance port (see below).
Remove air exhaust filter before flushing and reinstall after several minutes of running unit. Flush unit
after every 200 hours or after storing for long periods.
Do not use a flammable solvent or a solvent with a toxicity rating of 500ppm or
Note: Eye protection should be worn when flushing the unit.
STEP 1)
MAINTENANCE PORT
To flush the motor, turn off blower and remove the exhaust filter element (See page 10).
STEP 2)
Open the maintenance port, shown at left. Spray one or two ounces of safety solvent into the mainte-
nance port. Close the maintenance port. Run the blower in an open area away from sparks and
flames for a minimum of five minutes before reinstalling the exhaust filter.
AIR MOTOR FLUSHING PROCEDURE
Use Air Systems' Part #BAC-1001 safety solvent.
greater to flush the unit.
-9-