TROUBLESHOOTING
PROBLEM
Excessive vibration Air intake blocked
Possible internal damage
Possible external damage
Blower will not start
Circuit breaker trips
Faulty wall outlet
*Note: The use of generators are not recommended unless they are of sufficient output capacity.
MODEL SVB-E8EXP- Explosion-Proof Electric Blower
MOTOR TYPE
FULL LOAD
AMPERAGE
FLOW RATES
INLET/ OUTLET
SIZE
WEIGHT
SWITCH TYPE
NOISE LEVEL
FOR HAZARDOUS ENVIRONMENTS, ALWAYS USE AIR SYSTEMS' MODEL SV-CUPCND
CONDUCTIVE SADDLE VENT® VENTILATION KIT WITH AN EXPLOSION-PROOF
POSSIBLE CAUSE
Turn blower off and clear debris from intake
Turn blower off and inspect fan blades, shaft, and
housing for debris, damage, and loose screws.
Turn fan off and inspect blower housing
Wattage output of power source insufficient*
Extension cord improperly sized
Test voltage with meter
ITEM #
1
2
3
4
5
6
7*
8
SPECIFICATIONS
3/4 HP (.56 kw) Electric, 115 VAC/208-230 VAC, factory
wired with 25ft. Cord, no plug, explosion-proof Class I,
Div 1, Groups C and D, Class II, Div. 1, Groups E,F,G
Full Load
12.6 amps @ 115VAC
6.3 amps@ 208-230 VAC
Free Air: 1570 cfm
25 ft. Duct with One 90 degree bend: 1047cfm
8" Diameter (203 mm)
68 lbs.
Explosion-proof
76dbA @ 3 ft.
WARNING:
OR PNEUMATIC BLOWER.
-7-
SOLUTION
DESCRIPTION
EXPLOSION PROOF MOTOR
EXPLOSION PROOF ON/OFF SW ITCH
INTAKE/DISCHARGE GUARD - CONDUCTIVE
RUBBER FOOT
W HEEL HOUSING - CONDUCTIVE
POW ER CORD
BLOW ER W HEEL (SET SCREW S - FS5/16X038)
GROUND LUG
* LOCATED INSIDE W HEEL HOUSING
PART #
MTR003
ELSW 028
SVB-GRDCND
HDW R025
SVB-W H-CND
ELCB011-25
METL039
ELA051