Conditions for Use
The supply to the luminaire must include a fuse
which is capable of interrupting a 1500A short circuit
current. When used with steel wired armour or
braided cable the basket weave armour or braid is
unable to carry the cable load without fracture. The
cable must therefore be clamped and cleated to
prevent pulling on the cable being transmitted to
the cable terminations.
Luminaires supplied with the fitted 3 metre cable
must be protected from direct or vibrational impact
to prevent damage to the sheathing when
operated in ambient temperatures below -30°C.
Improper installation or operation of this luminaire
may invalidate the warranty. For maximum long
term reliability and light output, the luminaire must
be installed in free air. The High Bay luminaire design
incorporates an over- temperature control circuit
that reduces power to the LEDs should internal
temperatures reach a maximum level. In this event
light output may be reduced.
The length of the conductors between the cord
anchorage and the terminals shall be such that
should the cable or cord move out of the cord
anchorage,
the
current-carrying
become taut before the earthing conductor
Maintenance
To avoid personal injury, disconnect power to the
light and allow the unit to cool down before
performing maintenance.
WARNING:
This LED Luminaire should not require any electrical
maintenance. Never open the luminaire (other than
the junction box lid if supplied); there are no user-
serviceable parts inside.
Inspection
Within the scope of a maintenance or inspection
routine the following should be included: protective
hoses covering the connection cables. Cable
entries must be free of corrosion. Perform visual
mechanical and electrical inspections on a regular
basis. We recommend routine checks to be made
on
a
yearly
basis.
Frequency
environment
should
determine
recommended to follow an Electrical Preventive
Maintenance Program as described in NFPA 70B:
Recommended Practice for Electrical Equipment
The lens should be cleaned periodically, as needed,
to ensure continued photometric performance.
Clean the lens with a damp, non-abrasive, and lint-
free cloth. If not sufficient, use mild soap or a liquid
cleaner. Do not use and abrasive, strong alkaline, or
acid cleaners as damage may occur.
Inspect the cooling fins on the luminaire to ensure
that
they
are
free
of
any
contamination (i.e. excessive dust build-up). Clean
with a non-abrasive, damp cloth, if needed.
The light source of this luminaire is not replaceable;
when the light source reaches its end of life the
whole luminaire shall be replaced.
Repairs / Overhaul / Modification
The relevant national regulations which apply to the
maintenance / servicing of electrical apparatus in
explosive atmospheres shall be observed.
Page
4
ATEX/IECEx Rated LED High Bay Luminaire
Should the luminaire enclosure be damaged, only a
replacement will be permitted. In case of doubt, the
equipment should be returned to point of purchase
for inspection/repair/replacement.
WARNING:
Modifications to the device or changes to its design
are not permitted. The equipment must be
operated according to the intended purpose in a
perfect and undamaged condition
Disposal Recycling
When the apparatus is disposed of, the respective
national regulations on waste disposal should be
observed. WEEE (Waste electrical & electronic
equipment) registration number WEE/DC2678RY.
Technical Data
General Units
Rated Input Voltage:
HEA****P****
All Other Units
Supply Current:
HB(A/H)**4M
HB(A/H)**4P
HB(A/H)**MP
conductors
HBJ(A/H)**4M
HBJ(A/H)**4P
HBJ(A/H)**MP
HE(A/H)****P****
HE(A/H)****K****
HE(A/H)****G****
HE(A/H)****D****
HEJ(A/H)****P****
HEJ(A/H)****K****
HEJ(A/H)****G****
HEJ(A/H)****D****
HLA**4**
Operating
Ambient Temp:
Housing Material:
Housing Colour:
of
use
and
this.
It
is
Protection Glass:
Technical Data
HLA series
Category of application:
IECEx/ATEX
obstructions
or
Rated Input
Power:
Cable Entries:
Weight:
110-277VAC 50/60Hz
100-277VAC 50/60Hz
(Nominal @ 230V)
0.7A
0.7A
0.8A
0.7A
0.7A
0.8A
1.0A
0.7A
0.5A
0.4A
1.0A
0.7A
0.5A
0.4A
1.2A
-40°C to +60°C
Copper Free
Aluminium
Window Grey
Toughened
Soda-Lime Glass
Ex d IIB T5 Gb
Ex tb IIIC T100°C Db
IP66
Ex II 2GD
IECEx BAS 10.0074X
Baseefa 10 ATEX 0148X
315 W MAX.
Fixed 3 metre cable
18.1 Kg (40 lbs)
Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727
Tel: 732 919 3119
Technical Data:
HBH, HBJH, HEH, & HEJH series
Category of application:
165W Versions
Ex d IIB+H
T5 Gb
2
Ex tb IIIC T100°C Db
IP66
II 2GD
195W/235W
Version:
Ex d IIB+H
T4 Gb
2
Ex tb IIIC T135°C Db
IP66
II 2GD
165W Version
Junction Box:
Ex d e IIB+H
Ex tb IIIC T100°C Db
IP66
II 2GD
195W/235W Version
Junction Box:
Ex d e IIB+H
Ex tb IIIC T135°C Db
IP66
II 2GD
IECEx / ATEX:
IECEx
BAS
Baseefa12ATEX0070X
Cable Entries:
Fixed 3 metre cable
With Junction Box:
2x M20
(M25 optional
Weight:
11.4 Kg (25 lbs)
With Junction Box:
15.1 Kg (33.3 lbs)
Technical Data
HBA, HBJA, HEA, & HEJA series
Category of application:
165W Versions:
Ex d IIB T5 Gb
Ex tb IIIC T100°C Db
IP66
II 2GD
195W/235W
Version:
Ex d IIB T4 Gb
Ex tb IIIC T135°C Db
IP66
II 2GD
165W Version
Junction Box:
Ex d e IIB T5 Gb
Ex tb IIIC T100°C Db
IP66
II 2GD
195W/235W Version
Junction Box:
Ex d e IIB T4 Gb
Ex tb IIIC T135°C Db
IP66
II 2GD
IECEx / ATEX:
BAS 10.0074X
Baseefa 10ATEX0148X
Cable Entries:
Fixed 3 metre cable
With Junction Box:
2x M20
(M25 optional)
Weight:
11.4 Kg (25 lbs)
With Junction Box:
15.1 Kg (33.3 lbs)
9100127269899 REV H
Fax: 732 751 5778
www.dialight.com
T5 Gb