2.7. Diagnostic parameters

2.7.1. Operating hours
The sensor has a built-in counter that logs every hour in which the sensor has been operational. The
maximum hours that can be recorded are 2 147 483 647 hours: this value can be read from an IO-
Link master.
2.7.2. Number of power cycles [cycles]
The sensor has a built-in counter that logs every time the sensor has been powered-up. The value is
saved every hour. The maximum numbers of power cycles that can be recorded is 2 147 483 647.
This value can be read from an IO-Link master.
2.7.3. Maximum temperature – all time high [°C]
The sensor has a built-in function that logs the highest temperature that the sensor has been exposed
to during its full operational lifetime. This parameter is updated once per hour and can be read from
an IO-Link master.
2.7.4. Minimum temperature – all time low [°C]
The sensor has a built-in function that logs the lowest temperature that the sensor has been exposed
to during its full operational lifetime. This parameter is updated once per hour and can be read from
an IO-Link master.
2.7.5. Maximum temperature since last power-up [°C]
From this parameter the user can get information about what the maximum registered temperature has
been since start-up. This value is not saved in the sensor.
2.7.6. Minimum temperature since last power-up [°C]
From this parameter the user can get information about what the minimum registered temperature has
been since start-up. This value is not saved in the sensor.
2.7.7. Current temperature [°C]
From this parameter the user can get information about the current temperature of the sensor.
2.7.8. Detection counter [cycles]
The sensor logs every time the SSC1 changes state. This parameter is updated once per hour and can
be read from an IO-Link master.
2.7.9. Minutes above maximum temperature [min]
The sensor logs how many minutes the sensor has been operational above the maximum temperature.
The maximum number of minutes to be recorded is 2 147 483 647. This parameter is updated once
per hour and can be read from an IO-Link master.
2.7.10. Minutes below minimum temperature [min]
The sensor logs how many minutes the sensor has been operational below the minimum temperature.
The maximum number of minutes to be recorded is 2 147 483 647. This parameter is updated once
per hour and can be read from an IO-Link master.