Mechanical installation
4.4

Installation procedure

NOTICE
When you have ordered a version with flange, attach the hub first (
the "Assembly of the counter friction faces".
4.4.1
Install the hub onto the shaft
Abb. 4
Installing the hub onto the shaft
4
4.1 Key
1. Insert the key (4.1) into the shaft.
2. Press the hub (4) onto the shaft.
3. Secure the hub against axial displacement (for example, by using a circlip (4.2)).
INTORQ | BA 14.0197 | 04/2016
NOTICE
The toothed hub and screws must not be lubricated with grease or oil.
NOTICE
For reverse operations, we recommend also glueing the hub to the shaft.
Hub
4.2 Securing device
15 End shield
23), then continue with