It is not allowed to reduce the width of the
mounting plates [dimensions X on Fig. 5.4] with-
out prior formal authorization from Dhollandia.
§5.2 - Fixation of the mounting plates to the vehicle chas-
sis
Adjust the position of the mounting plates to the width of
the vehicle chassis.
Straighten the mounting plates, and make sure they stand
perpendicular to the lift frame. [See Fig. 5.6]. Tag-weld the
mounting plates to the HTL frame to hold them into posi-
tion during the initial mounting tests.
Follow the instructions below regarding the quantity of
mounting bolts, their size and position.
Position the mounting plates and bolts with due
diligence. Negligence could lead to overload
situations, damage to the HTL or vehicle chassis,
non-conformity with the bumper bar certificates,
and refusal at the vehicle inspection.
Apply an equal spread of all mounting bolts over the full
surface of the mounting plates. [See dimension X on Fig.
5.7].
If the mounting plates interfere with the subframe or cross-
bearers of the vehicle body, they can be shortened in
height, but with respect for the minimum requirements for
the bolts [see Fig. 5.7].
Verify that the HTL frame is correctly centred under the
vehicle chassis and body. [see Fig. 5.8]
DHOLLANDIA
5.6
5.8
25
X = max. 40 mm
5.7
DH-LSU.60
DH-LSU.90
Min. 8
Min. 10
M16 DIN6921—10.9
30.00 kgm