Télécharger Imprimer la page

Beko BEKOMAT 14 Instructions De Montage Et De Service page 12

Publicité

Function • Funcionamiento
Functionnement • Funcionamento
1
2
3
1
3
Switching sequence of valve in alarm mode
Secuencia de actuación de la válvula en el modo de alarma
Séquence d'activation de la vanne en mode Alarme
Sequência de ligação da válvula no modo de alarme
Alarm signal via potential-free contact
Mensaje de alarma a través de contacto sin potencial
Signal d'alarme délivré sur le contact sans potentiel
Sinal de alarme via contacto isento de potencial
12
5
6
2
4
english
The condensate flows through the feed
line (1) into the BEKOMAT unit and ac-
cumulates in the container (2). A capaci-
tive sensor (3) continuously registers the
liquid level and passes a signal to the
4
electronic control as soon as the con-
tainer is filled. The pilot valve (4) is then
activated and the diaphragm (5) opens
the outlet line (6) for discharging the
condensate.
When the BEKOMAT unit has been
emptied, the outlet line is closed again
quickly and tightly without wasting com-
pressed air.
Ready for operation
1
Voltage is being applied
Discharge procedure
2
Outlet line is open
Malfunction
3
Alarm mode is activated
Test
4
Manual drainage/alarm
The test button is used for checking
correct functioning.
Pressing
Effect
Short
Manual drainage
> 1 min
Alarm mode
When the microcontroller registers a
malfunction, the device will automatically
change to the alarm mode. The switching
sequence of the valve (see illustration)
continues until the fault is cleared (auto-
matically or through maintenance). The
red LED flashes as long as the device
is in the alarm mode.
Malfunctioning could be caused by, e.g.:
• Mistakes during installation
• Dropping below the necessary mini-
mum pressure
• Excessive condensate quantities (over-
loading)
• Blocked/shut off outlet line
• Extreme amount of dirt particles
• Frozen piping
If the fault is not cleared within the first
minute, a fault signal is triggered (see
illustration) which can be picked off as a
potential-free signal via the alarm relay.
(24 VDC version: see pages 10-13)
BEKOMAT 14, 14 CO, 14 CO PN25

Publicité

loading

Ce manuel est également adapté pour:

Bm14Bekomat 14 coBm14coBekomat 14 co pn25Bm14copn25