Operating Principle; Markings; Associated Equipment; Uses - Tractel dynafor Expert 0.5 Manuel D'installation, D'emploi Et D'entretien

Dynamomètre électronique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
The different possible combinations are described in
chapter 4. Associated equipment.

3.2. Operating principle

The operating principle of dynafor™ Expert is based on
the measurement using strain gauges of the elongation,
within the elastic limit, of a metal body subjstressected
to tensile.
The product operates in all directions.

3.3. Markings

See figure 1.
A
Fastening head
B
Coupling pin
C
B pin retention clips
D
Protector
E
Cover
F
On/Off (Start/Stop) button
G
Serial number
H
Operation indicator
I
Maximum sensor capacity
J
Shackle centering piece
K
Fastening ring
L
Cover fixing screw M
M
Battery compartment cover
N
Battery compartment (3 x "AA")
O
Manufacturer
QR code directing to the tracinfo platform containing
P
manual, adjustment certificate and data sheet

4. Associated equipment

The product is compatible with the following equipment:
Lifting accessories:
• Bow shackle
• Clevis shackle
• Clevis hook
Dynafor™
Bow
shackle
Expert 0.5t
47916
Expert 1t
47916
Expert 2t
47916
Expert 3.2t
47916
Expert 5t
47926
Expert 6.3t
47926
Expert 10t
47936
For details of lifting accessories, please refer to the
technical sheet, illustration of bow shackles in figure 2,
clevis shackles in figure 3 and clevis hooks in figure 4.
Lifting accessories not recommended by Tractel
must be correctly dimensioned according to the local
regulations in force.
Display devices:
• The dynafor™ HHD remote display unit offers multiple
functionalities including the reading and management
of 4 sensors up to a distance of 400 m in open air.
Codes: 293609 when purchased simultaneously with
a dynafor
Expert or Pro sensor
TM
Code: 293449 when purchased separately
• AL128 large display unit for high visibility, 128 mm
high digits with wireless communication up to 200 m
in open air.
Code: 293489
Threshold safety management module:
• dynafor™ monitoring unit (DMU) offering the same
functionalities as the dynafor™ HHD remote display
unit and allowing up to 5 relays to be controlled.
Code: 293479
Software:
• Loader software for downloading the data recorded
on the dynafor™ HHD remote display unit to a
computer.
Code: 293509
• Monitoring software allows load values to be
displayed, recorded and analysed live for up to 8
sensors. Requires the dynafor™ HHD remote display
unit.
Code: 68968
• dynafor™ app for displaying the load value of a
sensor from a smartphone or tablet via Bluetooth up
to 30 m in open air. Available on iOS and Android.

5. Uses

The supervisor must ensure that a technician is
tasked with installing the product. The supervisor must
Clevis
Clevis
shackle
hook
111407
111437
111407
111437
111407
111437
111407
111437
111417
111447
111417
111447
112207
112217
®
7
GB

Publicité

Table des Matières
loading

Table des Matières