ATTACHING AND CONNECTING THE ELEMENTS
1
Attaching
1) Attach the exterior camera at a height of 1.5 metres mounted on a flat wall.
2) First fit the rear support. Finish by tightening the screw at the bottom of the
panel.
3) Connect the camera wire (as shown in the diagram below) and insert the ca-
mera onto its support. Do not set up the camera where it is in direct contact with
the rain or sun. After installing and testing, place a clear silicon seal on the top and
sides of the exterior camera (not on the bottom) to avoid any risk of infiltration.
4) IMPORTANT : realize the setting of the melodie volume before install the monitor.
5) Attach the rear support of the monitor (at a height of 1.5 metres on a flat wall).
Connect the wires and insert the monitor onto its support.
WIRE SECTION :
Monitor-camera link
From 0 to 50 metres: use the 0.75 m² cable
CABLING DIAGRAM :
Gnd 18 V
A2 A1
MONITOR E7
Transformer
MONITOR
red
+18V
black
Gnd
2
3
Camera link - automatic opener or lock link
Camera - automated system
From 0 to 10 metres: use RVV2 *1mm² cable.
0.3s
3s
6s
ENGLISH
4
PANEL M2
6
5
4
3
2
1
12V700mA
3
5
Camera
MONITOR
1
2
2
1