Télécharger Imprimer la page

Velleman CAMCOLD1 Mode D'emploi page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Example: Controlling the P/T of camera n° 2.
o Press 2 and the CAM key to select camera n° 2.
o Tilt the joystick to control the camera P/T or use the Z-, Z+, F- or F+ key to control the lens.
c. Setting the Auto Scan
• Make the camera turn to the left using the joystick until the desired position has been reached.
• Press 92 and press the CALL key to set the left limit auto scan.
• Make the camera turn to the right using the joystick until the desired position has been reached.
• Press 93 and press the CALL key to set the right limit auto scan.
• Press the PAN key to make the camera scan from the left to the right. When the camera reaches the appointed
position, it will pause for 2 seconds and then move repeatedly from the left to the right. To stop the auto scan, just
tilt the joystick.
Example: Setting the auto scan for camera n° 2.
o Press 2 and then the CAM key to select the camera.
o Make the camera turn to the left using the joystick until the desired position has been reached.
o Press 92 and press the CALL key to set the left limit auto scan.
o Make the camera turn to the right using the joystick until the desired position has been reached.
o Press 93 and press the CALL key to set the right limit auto scan.
o Press the PAN key to confirm your settings. Camera n° 2 will auto scan within the predefined range.
9. Troubleshooting
Problem
The camera does not react when
connected to a power supply.
Light and image cannot be
controlled.
The camera cannot be controlled or
is moving erratically.
Fluctuating image.
Dimmed image.
10. Technical Specifications
Sensor
Pixels
Resolution
Illumination
Focal length
S/N Ratio
AGC
AEC
Sync System
Video Output
Communication
Baud Rate
P/T Range
CAMCOLD1
Possible Cause
Wrong connection.
Power deficiency.
Wrong camera ID or baud rate.
Wrong protocol.
Wrong RS485 terminator setting.
Non-compatible protocol.
Wrong camera ID.
Power deficiency.
Wrong RS485 terminator setting.
Wrong zoom setting.
Power deficiency.
Focus is manually set.
Dirty lens.
1/3" SONY Super HAD CCD
512 (H) x 492 (V)
380 TV lines
0.5 lux / F1.4
6 - 36mm
48dB
max. 29dB
1/50 – 1/100 000
internal
1.0Vpp / 75
RS485 (Pelco-P or Pelco-D)
9600 bit/s, 2400 bit/s
Pan: 0° - 355° / Tilt: 0° - 90°
- 5 -
Solution
Check the connection.
Check the power supply.
Reset the camera ID or baud rate.
Reset the protocol.
Reset the RS485 terminator setting.
Reset the DIP setting.
Reset the camera ID.
Check the power supply.
Reset the RS485 terminator setting.
Reset the zoom setting.
Check the power supply.
Set the camera.
Clean the lens.
VELLEMAN

Publicité

loading