Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Degree
Load (N/m
2
)
Knots
0
< 40
0-1
1
< 40
1-3
2
< 40
4-6
3
< 40
7-10
4
40
11-16
5
70
17-21
6
110
22-27
7
> 110
28-33
8
> 110
34-40
9
> 110
41-47
10
> 110
48-55
11
> 110
56-63
12
> 110
> 64
Wind resistance class of awning: Degree 5
Model
CONDOR 11
CONDOR 14
1 daN => 1 Kg
* Should it not be possible to guarantee the loads indicated in the data sheet, the wind resistance class of the product will be Degree 3
Rev. 7 - 06.2012
DATA SHEET 1 - STRENGTH AND EFFECTS OF THE WIND ACCORDING TO THE BEAUFORT SCALE
Km/h
m/s
Environmental situation
0-1
< 0,3
Calm
1-5
0,3-1,5
Light air
6-11
1,6-3,3
Light breeze
12-19
3,4-5,4
Gentle breeze
20-28
5,5-7,9
Moderate breeze
29-38
8-10,7
Fresh breeze
39-49
10,8-13,8
Strong breeze
50-61
13,9-17,1
Near gale
62-74
17,2-20,7
Gale
75-88
20,8-24,4
Strong gale
89-102
24,5-28,4
Storm
103-117
28,5-32,6
Violent storm
> 118
> 32,7
Hurricane
DATA SHEET 2 - ANCHORAGES
LOAD ON SINGLE ANCHOR CONSIDERING USE OF 6 ANCHORS ON THE WALL-MOUNTED ANCHORAGE PLATE
Degree 5
246 daN
393 daN
VELOMBRA SRL  USER MANUAL  CONDOR
Effects of the wind
Dead calm, smokes rises vertically.
Wind direction is indicated by smoke, not by flag.
Wind felt in face and the flag moves.
Leaves and small branches move.
Raises dust and paper, small branches are moved.
Small trees begin to sway.
Large branches move, umbrellas used with difficulty.
Large branches move, very difficult to walk against the wind.
Branches broken from trees, difficult to walk outdoors.
Tiles fall from roofs.
Trees uprooted.
Serious damage to buildings.
Immense damage.
Load on anchor *
Degree 4
141 daN
224 daN

DATA SHEETS

No. anchors
6
6
27 of 70