AXXAIR SAXX-210 Mode D'emploi page 63

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
INNOVATIVE ORBITAL SOLUTIONS
Join
experience
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
To
modify
the
overlap
activate/desactivate AVC in low pulse, you
have to use this key. Please refer to AVC-
OSC user manual for more information.
Save screen:
Total cycle time is displayed.
Welding energy is calculated as follow:
E = (k x U x I x 60) / V
E : J/mm
K : 0,7 (coef TIG)
U : in Volt (10+0,04 x I)
I : in Ampere
V : mm / min
This is the theoretical average energy of all
levels.
Press during 2s the saving button.
330B Route de Portes Les Valence - ZI Les Bosses - 26800 Etoile sur Rhône
Tél: +33 475 575 070 - Fax: +33 475 575 080 - commerce@axxair.com - www.axxair.com
- 63 -
English
offset
and/or

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Saxx-300

Table des Matières