Planning installation

Before starting to install your sauna heater:
Plan where to position the sauna heater (see The section
called Positioning the heater - normal installation, Page
2).
Plan where to position the control panel (see control panel in-
structions for correct positioning).
Plan where to position the sensor (see Figure 3, Page 2
and Figure 5, Page 3).
Position the inlet vent (see The section called Positioning the
inlet vent, Page 3).
Position the outlet vent (see The section called Positioning
the outlet vent, Page 3).
1
Figure 2: Schematic diagram of installation
1.
Sauna heater
2.
Control panel
3.
Sensor
4.
External on/off switch (option)
Positioning the heater - normal installation
DANGER! More than one heater can be installed in
!
the same sauna cabin.
Position the sauna heater:
on the same wall as the door (or the side wall if very close to
the door wall). The heater can also be positioned in a recess
(see Figure 5, Page 3).
at a safe distance from the floor, side walls and interior fittings
(see Figure 3, Page 2).
Position the sensor according to the diagram (see Figure 3, Page
2).
3
4
2
3
2
1
Figure 3: Positioning the heater - normal installation
1.
Minimum distance from side wall: 110 mm
2.
Sensor position: 200 mm from heater
3.
Sensor
4.
Minimum distance from back wall (with legs): 50 mm
5.
Sensor position: 40 mm from ceiling, regardless of ceiling
height
6.
Minimum distance from ceiling: 1030 mm
7.
Minimum distance from interior fittings: 100 mm
8.
Minimum ceiling height: 1900 mm
9.
Minimum distance: 20 mm
10.
Minimum distance from interior fittings: 30 mm
11.
Distance from floor: 100-270 mm (with legs: 100 mm)
If the wall that the sensor is to be installed on is made of highly
heat insulating material (e.g. concrete, brick) or of toughened
glass, the sensor can be installed directly above the heater
(above the centreline of the heater as seen from the front and
side see Figure 4, Page 2).
1
Figure 4: Sensor installation on ceiling on centreline of heater as
seen from the front and side
1.
200 mm
4
6
7
8
10
9
11
5