Beurer medical BC 40 Mode D'emploi page 105

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur
radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagne-
tic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the
location in which the BC40 Wrist Digital Blood Pressure Monitor is used exceeds the applicable RF compliance level above, the BC40
Wrist Digital Blood Pressure Monitor should be observed to verify normal operation. If abnormal performance is observed, additional
measures may be necessary, such as re¬orienting or relocating the BC40 Wrist Digital Blood Pressure Monitor.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m.
Table 4
Recommended separation distances between portable and mobile RF communications equipment and the BC40 Wrist Digital Blood Pressure Monitor
The BC40 Wrist Digital Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the BC40 Wrist Digital Blood Pressure Monitor can help prevent electromagnetic interference by main-
taining a minimum distance between portable and mobile RF communications equipment (transmitters) and the BC40 Wrist Digital Blood Pres-
sure Monitor as recommended below, according to the maximum output power of the communications equipment
Rated maximum output of
transmitter
(W)
0,01
0,1
1
10
100
For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres (m) can be estimated
using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W)
according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures,
objects and people.
Separation distance according to frequency of transmitter
150 kHz to 80 MHz
3
5 .
d
P
[
]
=
V
1
105
(m)
80 MHz to 800 MHz
3
5 .
d
[
]
P
=
V
1
0,12
0,38
1,2
3,8
12
800 MHz to 2.5 GHz
7
d
[
]
P
=
E
1
0,23
0,73
2,3
7,3
23

Publicité

Table des Matières
loading

Table des Matières