Magnetic length and angle measuring system MPI-15
Parameter
Description
Counting Direction
dir
Reference Value
OriGin
Offset Value
OFFSEt
Unit of measure
UnitS
Resolution
rES
Linear scale
Lin_cor
coefficient
Angular scale
AnG_cor
coefficient
Automatic Switch-off
AutoOFF
Switch-off time
t-out
Switch-off mode
on-OFF
Reference value
LoadOrG
loading mode
Incremental counter
CLr_reL
reset mode.
16
Available options
Press
to choose between
-dir
The parameter value is shown on the display. Press
to select the next number. Programmable value 0.00000 +/- 9.99999.
mark. Press
The parameter value is shown on the display. Press
mark. Press
to select the next number. Programmable value 0.00000 +/- 9.99999.
The parameter enables or disables the units of measure key in the operating mode.
Press
or
to choose between:
: the unit of measure can be changed by pressing the
EnAbLE
in the operating mode.
: the unit of measure cannot be changed in the operating mode.
diSAbLE
The parameter allows defining the resolution of the display.
Press
or
to choose between the available options: mm (0.1), inch (0.001),
degrees (0.01), degrees (0.1), degrees (1).
The parameter value is shown on the display. Press
mark. Press
to select the next number. Programmable value 0.00001 +/- 9.99999.
0.00000 cannot be accepted (the coefficient is automatically set to 1.00000).
The parameter value is shown on the display. Press
to select the next number. Programmable value 0.00000 +/- 9.99999.
mark. Press
0.00000 cannot be accepted (the coefficient is automatically set to 1.00000).
See Par. 8 for angle measurement description.
The parameter enables or disables the automatic switch-off.
Use
and
to choose between:
: the display automatically switches off after the selected period
EnAbLE
of time (parameter
).
t-out
: display does not switch-off automatically.
diSAbLE
Use
and
to choose between the available values (in hours).
Select 0.2;0.5;1;2;4;8 (in hours). When unused, the display automatically switch off after
the switch-off time.
The parameter allows defining the switch-off mode.
Use
and
to choose between:
: the display switches off immediately by pressing
dirECt
: the display switches off by pressing
dEL 'd
The parameter allows defining the reference value loading mode.
Use
and
to choose between:
: in the absolute mode (
EnAbLE
ABS
by pressing
: in the absolute mode (
diSAbLE
by pressing
+
The parameter allows defining the incremental counter reset mode.
Use
and
to choose between:
: in the incremental mode (◀◀◀) the incremental counter is set to zero
EnAbLE
by pressing
: in the incremental mode (◀◀◀) the incremental counter cannot be set to zero
diSAbLE
(the incremental counter is set to zero when the incremental mode is selected).
ELESA models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings.
(negative) and
(positive).
dir-
to increase the flashing number/
to increase the flashing number/
to increase the flashing number/
to increase the flashing number/
for about 4 seconds
) the absolute reference value is loaded
) the absolute reference value is loaded
ABS
Std Value
-dir
0.0
0.0
diSAbLE
key
mm 0.1
1.00000
1.00000
diSAbLE
0.2 h
dirECt
diSAbLE
diSAbLE