Wiring the 1625/2025 (Furnace) Honeywell Enhanced Air
Cleaner
f. Attach the quick connect terminals to the furnace EAC-1 and EAC-2 spade connections, which are
polarity neutral.
g. Attach the ground ring to furnace chassis ground.
NOTE:
The 1625/2025
NOTE:
The Honeywell Enhanced Air Cleaner should only be powered when airflow is present. The furnace
control EAC spade connections provide power only when the furnace blower is operating. If EAC
connections are not available, an alternative airflow sensing mechanism must be used to ensure the
Honeywell Enhanced Air Cleaner is only powered when airflow is present. Contact a local Honeywell
distributor for information on alternative airflow sensors.
Before proceeding to Startup and Operation on page 19:
I wired the Honeywell Enhanced Air Cleaner as instructed.
18
Honeywell Enhanced Air Cleaner is to be powered by 120 VAC at 60 Hz.
1625/2025 Wiring is complete. Go to page 19.