CARLO GAVAZZI ATEX CB32 Série Guide D'installation page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
Warning
!
Make sure only qualified personnel performs the installation/
maintenance/service
Before removing the sensor, or before connecting or disconnecting the wiring,
turn off the power supply. Do not disconnect unless the area is non-explosive.
Verify that the environmental temperature is within the temperature class
required for the area.
ATEX approved sensors
CB32CLN20QUAX
CB32CLN20SUAX
CB32CLN20RUAX
CB32CLN20QVAX
CB32CLN20SVAX
CB32CLN20RVAX
CB32CLN20QTAX
CB32CLN20STAX
CB32CLN20RTAX
Electrical specification
Supply Voltage
24VAC/DC
115VAC
230VAC
Operating temperature
Relay output
@24VAC/DC
@115VAC
@230VAC
Degree of protection
Max time-delay
4
Maintenance/service
Technical data
24V AC/DC, ON-delay
120V AC, ON-delay
230V AC, ON-delay
24V AC/DC, OFF-delay
120V AC, OFF-delay
230V AC, OFF-delay
24V AC/DC
120V AC
230V AC
20-28VAC/DC, 0-63Hz
100-135VAC, 57-63Hz
195-255VAC, 47-53Hz
o
-20
C - +40
SPDT
DC1: 5 ADCAVG
AC1: 5 AACrms
AC15: 2 AACrms
IP67
10 min
o
C