Télécharger Imprimer la page

IVT PL-C001P Notice D'utilisation page 7

Publicité

Les langues disponibles

Les langues disponibles

DESCRIPTION OF LED
1
2 3 4 5
DESCRIPTION OF OPERATING MODES
6 V mode
The 6 V-mode is suitable for charging rechargeable 6 V batteries with a capacity from 1.2 Ah (please observe the technical
data of the battery manufacturer concerning the maximum charging current). Press the MODE button again and again until
LED 2 flashes. After approx. 10 seconds the LED is constantly on and the charging procedure starts. The charging current is
1.0 A ± 10 %. At approx. 7.1 V the charging current will be reduced to 0.6 A. The charging end voltage is 7.2 V ± 0.2 V.
LED 5 indicates the charge status. When the LED is constantly on, the rechargeable battery is full.
12 V mode
The 12V mode is suitable for charging rechargeable 12 V batteries with a capacity from 1.2 Ah (please observe the technical
data of the battery manufacturer concerning the maximum charging current). Press the MODE button again and again until
LED 4 flashes. After approx. 10 seconds the LED is constantly on and the charging procedure starts. The charging current is
1.0 A ± 10 %. At approx. 14.2 V the charging current will be reduced to 0.6 A. The charging end voltage is 14.4 V ± 0.2 V.
LED 5 indicates the charge status. When the LED is constantly on, the rechargeable battery is full.
Regeneration mode
If a deep discharged rechargeable battery is connected to the charger, the regeneration mode is the first mode to start.
Pulsing charging currents are used to try and bring the deep discharged rechargeable battery to a voltage at which regular
charging function can be started. The maximum time of the regeneration mode is 20 minutes. If no adequate battery
voltage can be achieved during this time, the charger stops the process and the battery will be detected as defective.
Defective rechargeable batteries
The charger recognises defective rechargeable batteries automatically.
In this case the selected charging programme will not be started. LED 1 is on.
Protection against short circuits and reverse polarity
The charger recognises a short circuit or a battery which has been connected with wrong polarity automatically.
In this case the selected charging programme will not be started. LED 1 is on.
1
Error indication for battery connection
(short circuit, reversed polarity, battery is defective)
2
6 V mode
3
Mode button for charge mode selection
4
12 V mode
5
Charging status indicator
(flashes during charging process and is on when the
rechargeable battery is full)
7