Outlook diagram

Outlook diagram, see figure 2.
1
Hot water and pressure relief valve connection
2
Recirculation hole
3
Flow inlet connection (from the main unit)
4
Return outlet connection (to the main unit)
5
Cold water connection
6
Thermistor socket
7
Threaded thermistor hole for use with solar kit option. See
Installation manual EKSOLHW*.
8
Temperature and pressure relief valve connection
9
Remove the protection tape from the domestic hot water
tank
Domestic hot water tank model
EKHWS050B3VJU
(inch)
(mm)
EKHWS080B3VJU
(inch)
(mm)

Installation guidelines

Keep in mind the following guidelines when installing the domestic
hot water tank:
The installation location is frost-free.
Make sure to make the piping in size 1" or more (and reduce to
3/4" at the inlet of the tank) as to have sufficient water volume in
the piping between unit and domestic hot water tank.
Locate the domestic hot water tank in a suitable position to
facilitate ease of maintenance; remember access is required to
the electrical box. Refer to the grey-coloured zones indicated in
figure 2.
Provide a connection for the pressure relief valve blow-off and
drain.
To avoid back siphonage it is advised to install a non-return
valve on the water inlet of the domestic hot water tank in
accordance with local laws and regulations.
Take care that in the event of a leak, water can not cause any
damage to the installation space and surroundings.
EKHWS050+080B3VJU
Domestic hot water tank for air to water heat pump system
4PW56114-1
H1
H2
H3
H4
45.3
24.8
7.9
32.7
1150
630
200
830
63.0
24.8
7.9
32.7
1600
630
200
830

Installing the domestic hot water tank

1
Check if all domestic hot water tank accessories (see
"Accessories" on page 1) are enclosed.
2
Place the domestic hot water tank on a level surface.
3
Remove the protection tape from the domestic hot water tank
(See (8) in figure 2).
4
Apply thermal paste to the thermistor and insert the thermistor
as deep as possible in the thermistor socket. Fix using the nut
provided.

Connecting the water circuits

Refer to the chapter "Typical application examples" described in the
installation manual delivered with the indoor unit for details on
connecting the water circuits and the motorised 3-way valve.
Connecting the 3-way valve
1
Refer to the figure below before making the connection. Values
between brackets are the conversion from inch to mm.
0.51
3.03 (77)
(13)
14.37 (111)
1.50
2.64
(38)
(67)
Installation manual
5