5. Installation

5.1. Checks

 Check that the Sentry is undamaged and that you have received the correct version.
 Check that the data on the packing slip corresponds with the data shown on the product
received.
 Check that the voltage shown on the rating plate corresponds with the mains voltage.
If you have any problems and/or in the case of ambiguity:
please contact Simco-Ion or your regional agent.
5.2. Installation
5.2.1. Summary
Position the Sentry so that it blows freely over the area to be discharged.
The discharging time depends on distance and air velocity. Discharging will be faster if the
distance is reduced (to 15 cm min.) or the air velocity is increased.
5.2.2. Installation
1. Fit the Sentry with the handle, using both star knob screws.
Attention: Mount the lock washer between the handle and the box.
2. Place/mount the Sentry 30-90 cm away from the area to be neutralized.
3. Connect the Sentry to your machine or fit an earthed plug.
blue = neutral; brown = phase; yellow/green = earth
4. Put the [POWER] switch off [0].
5. Connect the Sentry to the mains voltage.
Warning:
- Make sure that the equipment is properly earthed.

6. Putting into use

1. Put the [POWER] switch to [1].
2. Set the required air velocity, using the [FAN SPEED] switch.
3. Point the air flow to the area to be discharged.
(Tilt the Sentry in the handle).