HEATER LOCATION AND CLEARANCE
Always maintain: (Pic. 1)
- 120 cm clearance from combustible materials,
- minimum 100 cm top clearance
- minimum 100 cm side clearance
- Heater must only be placed and used on a firm, level and stable underground.
GAS REQUIREMENTS
Use propane, butane or LGP only. See rating label on the appliance.
Maximum size of cylinder suitable for the appliance is Ø 30 cm x (60-65) cm
(high) (*). Inner dimension of stand with supporting
(*) height depends on the size and type of your gas regulator
Gas supply to the appliance from the gas cylinder: The appliance requires
approved gas hose in 140 cm length and a gas regulator (Hose and regulator
not included). The hose and regulator assembly must conform to local standard
codes.
Regulator maximum inlet pressure must not exceed 690 kPa
Regulator outlet pressure to be 28 mbar (2.8 kPa) to 37 mbar (3.7 kPa)
depending on countries.
The installation must conform to local codes, or in the absence of local codes,
to the standard for the storage and handling of liquid petroleum gases.
A dented, rusted or damaged gas cylinder may be hazardous and should be
checked by an authorized dedicated gas specialist,
Never use a gas cylinder with a damaged valve connection.
The gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
Never twist the flexible tubes and hoses.
Never connect an unregulated gas cylinder to the heater.
Disconnect the gas cylinder when the heater is not use.
Do not connect the gas cylinder directly to the appliance without regulator.
Use only the type of gas and the type of cylinder specified in these instructions.
LEAK TESTING
Gas connections on the heater are leak tested at the factory prior to shipment.
A complete gas tightness check must be performed at the installation site
due to possible mishandling in shipment and/or installation or because of
excessive pressure being applied to the heater. The heater must be checked-
with a full cylinder.
1. Make sure the safety control valve is in the OFF position.
2. Make a soapy water solution of one part liquid detergent and one part
water. The soapy water solution can be applied with a spray bottle, brush or
rag to all gas connections. Soap bubbles will appear in case of a Ieak.
WARNING: Never leak test while smoking!
WARNING: In the event of gas leakage, the appliance shall not be used or if
alight, the gas supply shall be shut off and the appliance shall be investigated
and rectified before it is used again.
3. Turn the gas supply ON. And check all the connections with the soapy
water solution. No bubbles may appear!
4. In case of a leak, turn off the gas supply. Tighten any leaking fittings, then
turn the gas supply ON and recheck. Contact your dealer or gas supplier for
assistance if bubbles continue to appear.