Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
The Beurer LE 60 air dehumidifier works according to the condensation principle. A fan positioned at the air
inlet draws in the humid ambient air over the evaporator and the adjoining condenser.
The condensation principle has two steps:
In the first step, the humid ambient air is cooled by the cold evaporator to just below dew point. The water
vapour contained in the ambient air then settles as condensate on the evaporator and trickles into the water
tank of the dehumidifier. Alternatively, a condensate hose can also be fitted to allow the condensed water
to drain away directly into an outlet.
In a second step, the now dehumidified, cooled air is reheated on the condenser and released back into the
ambient air. This way, the prepared, dry air mixes with the ambient air. With the ambient air continuously
circulating, humidity is drawn out of the room.
Evaporator /
heat exchanger
(cold)
Humid air
Fan
Water tank
The LE 60 air dehumidifier
– dehumidifies air in an eco-friendly way without chemical granulates
– has a control unit with illuminated LED indicators
– can collect the water extracted from the air in a built-in water tank or can drain it away through a conden-
sate hose directly into an outlet
– switches off automatically as soon as the water tank is full or the preset target air humidity level is reached
(a room humidity level of 50% is the most healthy level)
– features two fan speeds, including a swing function for better air distribution
– is equipped with an automatic defrost function
– protects items that are sensitive to humidity, e.g. furniture or musical instruments
– is suitable for room sizes of 40 m²-60 m².

2. Intended use

The LE 60 air dehumidifier is intended exclusively for dehumidifying air in enclosed indoor spaces.
The LE 60 air dehumidifier is intended exclusively for private use.
WARNING
– If you have a serious medical condition affecting the respiratory tract or lungs, please consult your
doctor about the use of the dehumidifier before use.
– The device is only intended for the purpose described in these instructions for use. The manufacturer
is not liable for damage resulting from improper or careless use.
Expansion valve
15
Condenser / heat
exchanger (warm)
Dry air
Compressor

Publicité

Table des Matières
loading

Table des Matières