Sicherheitshinweise Für Die Installation Nach Ul - Lenze L-force CPC 2800 Instructions De Montage

Table des Matières

Publicité

2
Sicherheitshinweise
Sicherheitshinweise für die Installation nach UL
2.2
Sicherheitshinweise für die Installation nach UL
Original − Englisch
Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File
Number E236341)
Ratings
Input 18 ... 30 V DC , max. 4 A
ƒ
ACCU−Pack and CAPS−Pack: max 0.6 A
ƒ
Max. ambient temperature 50 °C.
ƒ
Optional communication ratings:
ƒ
RS232−Connection: max. 3 A
USB−Connection: max. 1 A
PS/2−Connection: max. 1 A
LAN−Connection: Standard ISDN or RJ45
DVI−Connection: max. 1 A
J
Warnings!
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒ
ƒ
ƒ
Battery
ƒ
ƒ
ƒ
6
Use copper wire only.
AWG 18 ... AWG 12 (0.82 mm
Torque 5...7 lb−in (0.5 ... 0.6 Nm)
Replace battery with any from the list below, Part No. CR 2450
only. Use of another battery may present a risk of fire or
explosion.
Recommended CR2450 (R/C, BBVC2) types:
Renata Part.no. CR2450N, Sony Corp. part no. CR2450B, Toshiba
part no. CR2450, Varta part no. CR2450, Matsushita part no.
CR2450
Battery may explode if mistreated. Do not recharge, disassemble,
dispose of in fire or heat above 100 °C (212 °F).
Dispose of used battery according to the regulation of recycling
or waste.
2
2
... 3.3 mm
)
l
MA_CPCx8xx DE/EN/FR/ES/IT 2.0