Condensate Drainage; Electrical Connection - Helios KWL 45 RSF Notice De Montage Et D'utilisation

Masquer les pouces Voir aussi pour KWL 45 RSF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and operating instructions
CHAPTER 5
NOTE CONDENSATE
DRAINAGE
CHAPTER 6
ELECTRICAL
CONNECTION
m
WARNING
Installation kit facia KWL 45 RSF / KWL 45 RSF-L
4. Remove panel and position the panel frame centrally over the wall opening, mark the drill holes and drill (fig.12).
5. Place panel frame in horizontal position (fig.12) and screw into the wall (stainless steel screws must be provided on
site).
Then reattach the panel and screw (fig.13).
EXTERNAL WALL
All of the following installation steps can be found in the Installation and Operating Instruc-
tions KWL EC 45 (Print-No . 82 328)!
5 .0

Condensate drainage

During heating periods, condensation can form in the heat accumulator due to the process of heat recovery. The con-
densation water must be able to drain from the unit. A condensate drain gradient of 1-2° is ensured during installation
by the EPP front wedge which is pre-mounted to the wall installation sleeve (fig.7 and 14).
The protrusion of the condensate drain in the lower EPP half shell allows free condensate drainage in the external
facia (fig.15).
EPP front wedge
for condensate drain
INTERNAL WALL
All of the following information and instructions are intended solely for authorized electrici-
ans!
6 .0

Electrical connection

m DANGER
Touching live parts will result in electric shock .
Only connect with no voltage present!
– The electrical connection and initial start-up are to be carried out in accordance with wiring diagrams SS-1091/SS-
1093 and are only to be carried out by a certified electrician.
– The relevant standards, safety regulations (e.g. DIN VDE 0100, EN 50178), as well as the technical connection con-
ditions of energy suppliers are to be adhered to!
– A multipole mains section switch/isolator, with a minimum contact opening of 3 mm (VDE 0700 T1 7.12.2 / EN
60335-1) is mandatory!
– The power supply and the supply network must be sufficiently fused.
– The network connection must comply with IEC 62103, EN 50178 and IEC 60364, VDE 100
– Network configuration, voltage and frequency must be consistent with the rating plate information.
– The supply line must be introduced, so that no water can get in along the cable in case of water exposure.
fig .12
EXTERNAL WALL
fig .14
Section view
8
EN
fig .13
fig .15
Protrusion of the
EPP half shell
with condensate
drain
EXTERNAL WALL