8. Quick guide

Plan which wireless components you wish to use and how many of them. You can use a maximum of 8
channels. Draw up an installation plan.
Be aware of how many wire outputs you can use on your alarm centre and which output types you can set.
Determine the type of outputs (transistor output as open collector or relay) and the switch response of the
outputs. Does the transistor output switch against plus or ground if it is activated by the alarm centre? Does
the relay output work as an opener or closer if it is activated by the alarm centre?
Be aware of how many zones of the alarm centre you can use and which zone types you can set. Take into
account the wiring of the zones (Normally Open, Normally Closed, Closed Circuit, End of Line, Double End
of Line).
Test the wireless reception at the installation location of the Terxon 2WAY wireless module. To do so, you
can use the actual module (menu 4 – Display signal strength). To test the wireless reception at the
installation location of the Terxon 2WAY wireless module and at the installation locations of the wireless
components, you can also use wireless test box FU3801. To do so, place the wireless test box at the
possible installation location of the Terxon 2WAY wireless module. Trigger a transmission by the wireless
components. On the Secvest 2WAY outdoor sounder, activate the tamper switch. In order for the wireless
remote control 2WAY, the wireless operating unit 2WAY and the Secvest Key 2WAY wireless cylinder to
send a signal, activate these wireless components. In the next steps, place the wireless test box at the
possible mounting locations of the wireless components. Trigger a transmission by the Terxon 2WAY
wireless module by triggering an input. The test is easier if, instead of the Terxon 2WAY wireless module,
you use a wireless component, e.g. the wireless operating unit 2WAY, for sending a signal.
Install the Terxon 2WAY wireless module so that the terminal blocks are on the bottom.
Wire the Terxon 2WAY wireless module with the alarm centre. You should do this whilst the alarm centre
and the Terxon 2WAY wireless module are switched off.
Set the jumper for "CON1 FIT DISABLE REAR TAMPER" as desired.
Set the jumper for "CON2 + VSEL" as required.
Set the jumper for "CON3 INSTALLER MODE" to one contact only.
Set all DIP switches to the desired position.
Program the Terxon 2WAY wireless module, train the wireless components and, if appropriate, train the
desired PIN/proximity chip keys.
Test whether it works as desired.
Close the housing.