SET STATE
This input should be triggered if the alarm centre is fully activated. You then get a message on the
respective wireless components. For the actual display or signalling, please refer to the instructions of the
respective wireless component.
PSET STATE
This input should be triggered if the alarm centre is partially activated. You then get a message on the
respective wireless components. For the actual display or signalling, please refer to the instructions of the
respective wireless component.
Note on SET STATE and PSET STATE:
When you program the output/input mode of the alarm centre, keep in mind that the wireless
remote control 2WAY FU8100 has a receipt time of approx. 10 seconds and the wireless
control unit 2WAY approx. 130 seconds. If you choose longer times, you might have to use the
respective query key "?" in order to be informed of the current status of your alarm centre on
these operating elements.
FLT
This input should be triggered if the alarm centre is not ready for activation or a general fault has occurred.
You then get a message on the respective wireless components. For the actual display or signalling, please
refer to the instructions of the respective wireless component.
STRB
This input should be triggered if the strobe light of the Secvest 2WAY wireless outdoor sounder is to be
activated. Please also use this input if the activation confirmation is supposed to be signalled using the
strobe light.
BELL
This input should be triggered if the Secvest 2WAY wireless outdoor sounder and the Secvest wireless
indoor sounder are supposed to output the normal alarm sound (the normal alarm sounds if the "Bell" and
"Fire" inputs are triggered at the same time).
TEST
This input should be triggered if the alarm centre is in setup mode. Secvest 2WAY wireless outdoor sounder
FU8220 has a setup mode, i.e. you can open the 2WAY wireless outdoor sounder without the siren being
activated due to tampering. The Terxon 2WAY wireless module sends the Secvest 2WAY wireless outdoor
sounder a signal for activating setup mode if the "TEST" input is triggered. If your alarm centre does not
have a corresponding "Access setup mode" output type, you can set this jumper on both contacts on the
"CON3 INSTALLER MODE" jumper connections so that the Terxon 2WAY wireless module sends a signal
for accessing setup mode to the Secvest 2WAY wireless outdoor sounder.
FIRE
This input should be triggered if the Secvest 2WAY wireless outdoor sounder and the Secvest wireless
indoor sounder are supposed to output the fire alarm sound (the normal alarm sounds if the "Bell" and "Fire"
inputs are triggered at the same time).
ENTRY
This input should be triggered if the Secvest wireless indoor sounder is supposed to output the "Entry delay
time running" sound. For some alarm centres, you might have to summarise the inputs Entry, Exit and Exit
fault and set them together on an output of the alarm centre of the type "Input/output follows". For
combinations with "Exit" and/or "Exit Fault", the "Entry delay time running" signal is output.
EXIT
This input should be triggered if the Secvest wireless indoor sounder is supposed to output the "Exit delay
time running" sound. For combinations with "Exit Fault", the "Exit delay time running" signal is output.