8 Teknik veriler
Kablo şemasındaki metnin tercümesi
İngilizce
(1) Main power connection
For preferential kWh rate power
supply
Indoor unit supplied from outdoor Dış üniteden beslenen iç ünite
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
Only for ***
(3) User interface
Only for LAN adapter
Only for remote user interface
EKRUDAS
(4) Domestic hot water tank
3 wire type SPST
Booster heater power supply
Only for ***
SWB
(5) Ext. thermistor
SWB
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
Continuous
DHW pump output
DHW pump
Electrical meters
For safety thermostat
Montaj kılavuzu
216
Tercüme
(1) Ana güç bağlantısı
İndirimli elektrik tarifeli güç
beslemesi için
Normal elektrik tarifesi güç
kaynağı
Yalnızca normal elektrik tarifesi
güç kaynağı için (standart)
Yalnızca indirimli elektrik tarifeli
güç beslemesi için (dış)
Dış ünite
İndirimli elektrik tarifesi güç
beslemesi kontağı: 16 V DC
tespiti (PCB tarafından beslenen
gerilim)
Anahtar kutusu
İç ünite için normal elektrik
tarifesi güç kaynağı kullanın
(2) Yedek ısıtıcı güç beslemesi
Sadece *** için
(3) Kullanıcı arayüzü
Sadece LAN adaptörü için
Sadece oda termostatı olarak
kullanılan kullanıcı arayüzü için
(EKRUDAS)
(4) Kullanım sıcak suyu boyleri
3 telli tip SPST
Buster ısıtıcı güç beslemesi
Sadece *** için
Anahtar kutusu
(5) Harici termistör
Anahtar kutusu
(6) Sahada temin edilen
seçenekler
12 V DC darbe tespiti (PCB
tarafından beslenen gerilim)
PCB tarafından sağlanan
230 V AC
Devamlı akım
Kullanım sıcak suyu pompa çıkışı
Kullanım sıcak suyu pompası
Elektrik sayaçları
Güvenlik termostatı için
İngilizce
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
solar pump connection, alarm
output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Refer to operation manual
Solar input
Solar pump connection
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Tercüme
Demaraj akımı
Maksimum yükleme
Normal kapama
Normal açma
Güvenlik termostatı bağlantısı:
16 V DC tespiti (PCB tarafından
beslenen gerilim)
Kesme vanası
Anahtar kutusu
(7) Seçenek PCB'leri
Alarm çıkışı
Harici ısı kaynağına geçiş
Maksimum yükleme
Minimum yükleme
Yalnızca talep PCB'si seçeneği
için
Yalnızca dijital G/Ç PCB'si
seçeneği için
Seçenekler: harici ısı kaynağı
çıkışı, güneş pompası bağlantısı,
alarm çıkışı
Seçenekler: Açık/KAPALI çıkışı
Güç sınırlandırma dijital girişleri:
12 V DC / 12 mA tespiti (PCB
tarafından beslenen gerilim)
Kullanım kılavuzuna bakın
Güneş enerjisi girişi
Güneş pompası bağlantısı
Alan soğutma/ısıtma Açık/
KAPALI çıkışı
Anahtar kutusu
(8) Harici Açık/KAPALI
termostatlar ve ısı pompası
konvektörü
İlave çıkış suyu sıcaklığı bölgesi
Ana çıkış suyu sıcaklığı bölgesi
Yalnızca harici sensör için
Yalnızca ısı pompası konvektörü
için
Yalnızca kablolu Açık/KAPALI
termostat için
Yalnızca kablosuz Açık/KAPALI