Technical Data; Accessories - Riello RS 300/M BLU Manuel D'entretien

Table des Matières

Publicité

TECHNICAL DATA

MODEL
TYP
max.
OUTPUT
(1)
min.
FUEL
Gas pressure at maximum delivery.
Gas: G20/G25
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
FAN MOTOR
(star-delta starting for RS 400, RS 500
und RS 800)
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
CONFORMITY TO EEC DIRECTIVES
NOISE LEVELS
(EN15036-1)
(3)
APPROVAL
class 3 (EN 676)
Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Pressure at pressure switch test point 20)(A)p.12 with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)

ACCESSORIES

(optional)
RADIO DISTURBANCEPROTECTION KIT
If the burner is installed in places particularly subject to radio disturbance (emission of signals exceeding 10 V/m) owing to the presence of an
INVERTER, or in applications where the length of the thermostat connections exceeds 20 metres, a protection kit is available as an interface
between the control box and the burner.
BURNER
RS 300/M BLU - RS 400/M BLU - RS 500/M BLU - RS 800/M BLU
Code
KIT FOR MODULATING OPERATION
Output power regulator kit RWF40
There are two components to order:
• the Output power regulator to install on the burner;
• the Probe to install on the heat generator
Parameter to control
Adjustment field
Temperature
- 100...+500°C
Pressure
0...2.5 bar
0...16 bar
UV CELL KIT
KIT INTERFACE ADAPTER RMG TO PC
POTENTIOMETER KIT FOR THE INDICATION OF LOAD POSITION
SOUNDPROOFING BOX KIT
KIT CONTINUOUS PURGING
GAS TRAIN ACCORDING TO REGULATION EN 676
Note.
Riello S.p.a. declines all responsibility for the addition of safety devices not provided for herein.
RS 300/M
BLU
859 T
kW
1350 - 3800
kW
500
NATURAL GAS: G20 (methane) - G21 - G22 - G23 - G25
(2)
mbar
23.3 / 32.7
Intermittent
Boilers: water, steam, diathermic oil
°C
0 - 40
°C max
60
rpm
2900
V
230/400
kW
4.5
A
15,8 - 9,1
V1 - V2
230 V - 1 x 8 kV
I1 - I2
1 A - 20 mA
kW max
6
IP 54
90/396 - 89/336 - 2004/108 - 73/23 - 2006/95 - 2006/42
dBA
82
CE
0085BR0480
3010386
Probe
Type
Code
PT 100
3010110
Probe with outlet
3010213
4...20 mA
3010214
: see page 23.
RS 400/M
RS 500/M
BLU
BLU
860 T
856 T
1830 - 4590
2500 - 5170
950
1000
34.3 / 40.2
37.6 / 56.1
3N ~ 400/230V
+/-10% 50 Hz
2900
2900
400/690
400/690
7.5
9.2
16 - 9
18 - 10.5
9
11
85
88
0085BR0481
0085BO0341
Output power regulator with signal
4-20 mA, 0-10V
There are two components to order:
• the Analogic signal converter;
• the Potentiometer
Output power regulator
Type
Code
RWF40 BASIC
3010356
RWF40 HIGH
3010357
code 3010359
code 3002719
code 3010402
code 3010376
code 3010094
8
RS 800/M
RS 500/M
BLU
BLU
887 T
856 T80
3500 - 8100
2500 - 5170
3500 - 8100
1200
1000
45.5 / 81.2
37.6 / 56.1
3N ~ 380/220
+/-10% 60 Hz
2900
3520
400/690
380/660
21
9.2
40 - 23
15,5 - 9
24
11
88
88
0085BT0337
-
Analogic signal
Potentiometer
converter
Type
Code
Type
ASZ...
3010402
E5202
RS 800/M
BLU
887 T80
1200
45.5 / 81.2
3520
380/660
21
43.6 - 25.2
26
88
-
Code
3010390