Relay Connection; Connecting The Washer; Connection Of The Ethernet Cable - uideorec ULISSE COMPACT HD PTZ Manuel D'instructions

Caméra ptz extérieure pour images détaillées en fyll hd et hautes performances
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82

7.1.4.3 Relay connection

The relay can be used for low working
voltages only (up to 30Vac or 60Vdc) and with
a maximum current of 1A. Use cables with a
section suitable for the load to be controlled
and use cables with a minimum section of
0.25mm² (AWG 24) and maximum section of
1.5mm² (AWG 16).
The R1A and R1B relay clamps are located in the J4
connector. The relay does not have polarity making it,
therefore, irrelevant to use clamp A or B of the same
relay for AC or DC voltages.
RELAY CONNECTION
Terminal
R1A
R1B
Tab. 5
For further information refer to the relative
chapter (9.2.10 Digital I/O, page 28).

7.1.4.4 Connecting the Washer

For further details on configuration and use,
refer to the relative manual.
When the washing system is enabled, the
relay 1 is used exclusively for the activation of
the pump (9.2.12 Washer, page 28).
MNVCUCHD_1511_EN
Description
Relay 1, Terminal A
Relay 1, Terminal B

7.1.4.5 Connection of the Ethernet cable

Connect the J1 connector of the secondary connector
board using a 5E category, or higher, UTP cable (
7.1.4.1 Description of the secondary board, page 16).
The example below shows a typical installation.
UTP cat 5E
Personal
Computer
Fig. 15
Hub / Switch
UTP cat 5E
17

Publicité

Table des Matières
loading

Table des Matières