Télécharger Imprimer la page

Rockwell Automation Allen-Bradley Guardmaster SPRITE 3 Mode D'emploi page 3

Publicité

Deutsch / Français
BETÄTIGER-RÜCKZUGABSTAND /
(a)
Distance d'extraction de l'émetteur
T e c h n ic al S pec if ic atio ns
(d)
Conforming to standards
EN 1088, EN 60947-5-1, EN 292,
EN 60204-1
Safety contacts
2 N/C direct opening
1 N/C, 1 N/O direct opening
Designation/Utilisation cat.
B600/AC-15
(Ue)
600V
(le)
0.6A
0.72A
P600/DC-13
(Ue)
600V
(le)
0.2A
0.27A
Thermal current (lth)
5A
Min. current
5V 5mA DC
Typical contact resistance
5mΩ
Safety contact gap
>2mm
Rtd. insulation voltage
(Ui) 500V
Rtd. impulse withstand voltage
(Uimp) 2500V
Auxiliary contacts
1N/O
(available with 1N/C safety contacts)
Pollution degree
3
Shaft rotation to achieve contact
Adjustable
operation
2 N/C
11° (max) 3° (min)
Adjustable
1 N/C, 1 N/O
11° (max) 3° (min)
Break contact minimum force
20 cNm
Case material
UL Approved glass filled polyester
Actuator material
Stainless steel
Protection
IP 67
Conduit entry
M16 or Pg 9
Operating temperature
-20° C to 80° C
Fixing
2 x M4
Cleaning
May be steam cleaned
Mechanical life
1,000,000
Colour
Red
Torque settings
Fixing bolts
2.5 to 3 Nm
Lid screws
0.4 to 0.45 Nm
Terminal screws 0.9 to 1.0 Nm
Head screws
0.4 to 0.45 Nm
Note: The safety contacts of the Guardmaster switches are described as
normally closed (N/C) i.e. with the guard closed, actuator in place (where
relevant) and the machine able to be started.
INFORMATION IN REGARD TO UL508
Use copper conductors only.
Use Polymeric conduit only.
Use one conduit entrance for field connections.
When used in elevated ambients, temperature rating of
field wiring shall not be less than ambient.
Terminal tightening torque: 9 in/lb.
Contact block tightening torque: 9 in/lb.
Electrical spec of rating code B600.
Max current: 120V AC - make 30A, break 3A.
240V AC - make 15A, break 1.5A.
Max. V/A: make 3600, break 360.
25
12.5
Ø 10
Entspricht Normen:
Sicherheitskontakt
Verwendungskategorie
500V
240V
120V
B600/AC-15
1.5A
3A
500V
250V
125V
P600/DC-13
0.55A
1.1A
Thermischer Strom (lth)
Mindeststrom
Typischer Kontaktwiderstand
Sicherheitskontaktlücke
Nennisolationsspannung
Nennsteh-Stoßspannung
Hilfskontakte
Verunreinigungsgrad
Wellendrehung für Kontakt
Min.kraft zur Kontaktunterbr.
Gehäusematerial
Schutzart
Rohrleitungseingang
Betriebstemperatur
Befestigung
Reinigung
Mech. Lebensdauer
Farbe
Drehmomenteinstellung:
Befestigungsbolzen
Deckelschrauben
Anschlußschrauben
Die Schrauben am Schalterkopf
Hinweis: Die Sicherheitskontakte der Guardmaster Schalter werden als Öffner
beschrieben, d.h. das Schutzgitter ist geschlossen, der Betätiger angebracht (wo
erforderlich) und die Maschine kann gestartet werden.
Information bzgl. UL 508
Nur Kupferleiter verwenden.
Nur Kunststoffkabelkanal verwenden.
Einen Kabeleinlauf für Anschlüsse im Freien verwenden.
Bei Einsatz in höheren Umgebungstemperaturen darf der
Temperaturnennwert der Verdrahtung die
Umgebungstemperatur vor Ort nicht unterschreiten.
Klemmenspanndrehmoment: 50 cm/kg.
Kontaktblock-Spanndrehmoment: 50 cm/kg.
Elektrisches Rating B600
Max. Strom: 120 VAC -Ein 30 A, Aus 3A
Max. VA: Ein 3600, Aus 360
75
12.5
R 2.1
3
34.5
36
Te c hnis che Daten
EN 1088, EN 60947-5-1, EN 292,
EN 60204-1
2 N/C direkt öffnender
1 N/C or 1 N/O direkt öffnender
(Ue)
600V
500V
240V
(le)
0.6A
0.72A
1.5A
(Ue)
600V
500V
250V
(le)
0.2A
0.27A
0.55A
5A
5V 5mA DC
5mΩ
>2mm
(Ui) 500N
(Uimp) 2500N
1 N/0 (Lieferbar mit 1 Sicherheits-
Öffnungskontakt)
3
Verstellbar
2 N/C
11° (max) 3° (min)
Verstellbar
1 N/C, 1 N/O 11° (max) 3° (min)
20 cNm
UL genehmigtes glas-gefülltes Polyester
IP 67
1 x M16 or 1x Pg 9
-20°C bis 80°C
2 x M4
mögl. Reinigung mit Hochdruckdampf
1,000,000
rot
2.5 bis 3 Nm
0.4 bis 0.45 Nm
0.9 bis 1.0 Nm
0.4 bis 0.45 Nm
240 VAC -Ein 15 A, Aus 1.5A
Actuator withdrawal distance
(a)
from full insertion: 2 N/C
11/12
21/22
Contact Open
(a)
Actuator withdrawal distance
from full insertion: 1 N/C + 1 N/O
11/12
23/24
Contact Open
S pec i fi c ati on s tec h n i qu es
Conforme aux normes
Contact de sécurité
Catégorie d'utilisation
B600/AC-15
(Ue)
120V
(le)
3A
P600/DC-13
(Ue)
125V
(le)
1.1A
Courant thermique (lth)
Courant min.
Résistance de contact
Espace contact de sécurité
Tension d'isolement
Tension de tenue aux ondes de choc (Uimp) 2500V
Contacts auxiliaires
Degré de pollution
Rotation de l'axe pour obtenir le Réglable
fonctionnement du contact 2 N/C 11° (maxi) 3° (mini)
1 N/C, 1 N/O 11° (maxi) 3° (mini)
Force minimum rupture contact
Boîtier
Protection
Presse-étoupe
Température
Fixation
Nettoyage
Vie mécanique
Couleur
Force de torsion:
Boulons de fixation
Vis du couvercle
Vis terminales
Les vis de la tête
Note : Les contacts de sécurité des interrupteurs Guardmaster sont décrits
comme étant normalement fermés (N/C) i.e. avec la porte fermée,
l'actionneur en place (où il a lieu d'être) et la machine prête à fonctionner.
Informations en rapport avec la norme
UL508
Utiliser uniquement des conducteurs en cuivre.
Utiliser uniquement des conduits en polymère.
Utiliser une seule entrée de conduit pour les connexions.
Pour une utilisation dans des températures ambiantes
élevées, prévoir des câbles électriques d'une classe leur
permettant de supporter ces températures.
Couple de serrage des bornes : 9 pouces/livre.
Couple de serrage des contacts : 9
B600.
Courant max: 120 VAC - Enclenchement 30A - Rupture 3A
140 VAC - Enclenchement 15A - Rupture 1.5A
Max V/A Enclenchement 3600 - Rupture 360
Contact Closed
Contact Closed
EN 1088, EN 60947-5-1, EN 292,
EN 60204-1
2 N/C ouverture directe
1 N/C ou 1 N/C ouverture directe
600V
500V
240V
120V
0.6A
0.72A
1.5A
3A
600V
500V
250V
125V
0.2A
0.27A
0.55A
1.1A
5A
5V 5mA DC
5mΩ
>2mm
(Ui) 500V
1N/0 (Pour la version 1 N/C de sécurité)
3
Réglable
20 cNm
polyester chargé verre approuvé UL
IP 67
1 x M16 ou 1 x Pg 9
-20°C à 80°C
2 x M4
Peut être nettoyé à la vapeur
1,000,000
Rouge
2.5 à 3 Nm
0.4 à 0.45 Nm
0.9 à 1.0 Nm
0.4 à 0.45 Nm
pouces/livre.ivant

Publicité

loading

Ce manuel est également adapté pour:

40397