Trouble Shooting; Installation, Relocation And Inspection - Mitsubishi Electric Mr. SLIM SLZ-M-FA Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37

7. Trouble Shooting

Having trouble?
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display
is faint, or signals are not received by the indoor unit unless the remote
controller is close.
After battery installation/replacement of remote controller, part of function
cannot be used.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is flashing.
The wireless remote controller does not operate (the indoor unit beeps
4 times).
The indoor unit which is not operating becomes warm and a sound, similar
to water flowing, is heard from the unit.

8. Installation, relocation and inspection

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
Caution:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an explosion.
• Where there is much machine oil.
• Salty place such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where there is oil splashing or much oily smoke.
Here is the solution. (Unit is operating normally.)
I The indoor operation sound level is affected by the acoustics of the
particular room as shown in the following table and will be higher than
the noise specification, which was measured in an echo-free room.
High sound-
absorbing
rooms
Broadcasting
Location
studio, music
examples
room, etc.
Noise levels
3 to 7 dB
I The batteries are low.
Replace the batteries and press the Reset button.
I If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
I Please check that the clock setting is completed. If clock setting is not
done, please complete.
I The self diagnosis function has operated to protect the air conditioner.
I Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
I Switch the auto mode setting to the AUTO (single set point) mode or
AUTO (dual set point) mode. For details, refer to the included Notice
(A5 sheet) or the Installation Manual.
I A small amount of refrigerant continues to flow into the indoor unit
even though it is not operating. (Connected with MXZ/Branch box)
Inverter type
fluorescent lamp
To prevent the effect
of a fluorescent lamp,
keep it away as far
apart as possible.
To prevent picture
distortion or
noise, keep 1 m
or more apart.
Radio
Low sound-
Normal rooms
absorbing
rooms
Reception
Office, hotel
room, hotel
room
lobby, etc.
6 to 10 dB
9 to 13 dB
Wall, etc.
Well-
ventilated dry
place
100 mm or
more
400 mm
TV
or more
15
en

Publicité

Table des Matières
loading

Table des Matières