Télécharger Imprimer la page

LEGRAND Wattstopper LMDI-100-U Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

Attach the LMRJ Cable
The DLM local network uses free topology low voltage wiring. The LMDI-100 can connect anywhere on the DLM local network.
CAUTION: TO CONNECT A COMPUTER
TO THE DLM LOCAL NETWORK USE THE
LMCI-100. NEVER CONNECT THE DLM
LOCAL NETWORK TO AN ETHERNET
PORT – IT MAY DAMAGE COMPUTERS AND
OTHER CONNECTED EQUIPMENT.
With Flow Control
LMDI-100
RxD Pin 1
TxD Pin 2
RTS Pin 4
CTS Pin 5
GND Pin 10
With Flow: Use RTS and CTS for LMDI-
100 and DCE (Data Communication
Equipment) device such as a computer or
modem. Use DSR, DCD and DTR.
No Flow Control
LMDI-100
RxD Pin 1
TxD Pin 2
GND Pin 10
No Flow: Do not use RTS and CTS
for LMDI-100, but for DCE (Data
Communications Equipment) device such
as computer or modem. Use DSR, DCD
and DTR.
MOUNTING AND WIRING
TERMINAL CONNECTION
LMDI-100
DCE DEVICE
RxD Pin 1
CONNECTION
TxD Pin 2
RxD
RTS Pin 4
TxD
RTS
CTS Pin 5
GND Pin 10
CTS
DCD
DTR
With Flow: Use RTS and CTS for LMDI-
DSL
100 and DTE (Data Terminal Equipment)
device.
GND
Upon initial power up, the LMDI-100 requires about 15 seconds of warm-up time.
During this time the unit will turn ON the top LED marked as Not Used. It will then
enable its RS-232 port with the last assigned parameters, and engage each of its LEDs
according to current network status.
The default COM parameters at power up are 19200 baud, 8 bits, no parity, 1 stop bit,
commonly written as "19200- 8-N-1".
DCE DEVICE
CONNECTION
RxD
Rx: A green LED that blinks when a message has been received from a 3rd party
TxD
controller at a rate of no more than twice per second.
GND
Tx: A green LED that blinks at a rate of twice per second when a message has been
RTS
sent to a 3rd party controller twice per second.
CTS
Config: A red LED that blinks while the system is in PnL. Sets the baud rate back
DSR
to factory default (19200 bps) for servicing when the Config button is pressed for 10
DCD
seconds.
DTR
Switch
LMRJ Cables
Occupancy Sensor
With Flow Control
DTE DEVICE
CONNECTION
RxD
TxD
RTS
CTS
GND
POWER UP FUNCTIONALITY
LED INDICATORS
2
Room
Controller
RS-232 Data Wiring
Input/Output to Third Party
Device (e.g.: AV system or
shade controller)
LMDI-100 Serial
Data Interface
No Flow Control
LMDI-100
RxD Pin 1
TxD Pin 2
GND Pin 10
No Flow: Do not use RTS and CTS
for LMDI-100 or DTE (Data Terminal
Equipment) device.
Line Voltage
Loads
1
2
DTE DEVICE
CONNECTION
RxD
TxD
GND

Publicité