TECHNICAL DATA
Receiving Lens
Measuring Range
Minimum distance
Maximum distance
Distance Measurement
Typical tolerance
(applies for 100 % target refl ectivity (white painted wall), low background illumination, 25 ºC)
Maximum tolerance
(applies to targets with lower refl ectivity, high background illumination, or temperatures
approaching the lower/upper limit)
Smallest unit displayed
Laser Spot Size
16 m distance:
Laser Class
Laser Type
Laser Radiation
Vertical Angle
Horizontal Angle
Display Type
Laser auto off time
Device auto off time
Power Type
Battery Life
Operating Temperature Range
Storage Temperature Range
Weight without Battery
Dust and Water resistance
SPECIFIED CONDITIONS OF USE
The laser distance measurer can be used for measuring distances and tilts.
Do not use this product in any other way as stated for normal use.
ENGLISH
LDM 45
15 mm x 9 mm
45 meters (Tolerance: 45.1 m)
0.05 meters
± 2.0 mm
(an addidional tolerance of 0.1 mm/m should be taken into account)
± 4.0 mm
(an addidional tolerance of 0.15 mm/m should be taken into account)
1 mm
25 x 50 mm
2
635 nm, < 1 mW
± 1 degree
+ 1 degree
LCD (31.5 mm x 40 mm)
90 sec
180 sec
AAA 2x (Alkaline Battery)
8000 (Single Measure)
0°C to +40°C
-10°C to +60°C
87 g
IP54

ERROR CODE TABLE

Code
Err500
LDM 100
18 mm
100 meters (Tolerance: 101 m)
0.05 meters
± 2.0 mm
(an addidional tolerance of 0.1 mm/m should be taken into account)
± 4.0 mm
(an addidional tolerance of 0.15 mm/m should be taken into account)
1 mm
25 x 50 mm
2
635 nm, < 1 mW
± 1 degree
+ 1 degree
LCD (31.5 mm x 40 mm)
90 sec
180 sec
AAA 2x (Alkaline Battery)
8000 (Single Measure)
0°C to +40°C
-10°C to +60°C
122 g
IP54
Description
Solution
Hardware problems
Turn the meter off and back on. If the problem
remains, return the meter to the nearest service
center.