OPERATING AND MAINTENANCE MANUAL FOR AQUASTEAM,
TROUBLE-ShOOTING
Please note: the information in the table below and the action to take is intended for the use
of the assistance centre personnel and others qualified to install/maintain the equipment.
Error message
Critical errors
Non-critical errors
For any situations not covered in this table, consult your approved assistance centre or contact the company
direct.
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or replace this manual.
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes without having to give prior warning or replace this manual.
AQUASTEAM MAXI, EASYSTEAM
Meaning
A peripheral device
Lack of
has not been found
communication
on the bus.
with 1 or more
devices.
The panel
Lack of
signalling the error
communication
is not receiving
with 1 or more
polling from the
devices.
master.
Peripheral device
Lack of
not recognised by
communication
the bus.
with 1 or more
devices.
Boiler full too soon. The boiler filled
too quickly during
initial rinsing or final
emptying.
Boiler not yet full.
The boiler didn't
fill within the
prescribed time
limit during initial
rinsing or final
emptying.
Boiler not yet
The water level in
empty.
the boiler remained
too high for too
long during initial
rinsing or final emp-
tying.
Error
Cause
One of the devices
is not receiving
power or is not
connected.
One of the devices
is not receiving
power or is not
connected.
One of the devices
is not receiving
power or is not
connected.
Outlet valve not
working.
Lack of water in
the system or the
inlet valve filter is
blocked.
Outlet
valve
working.
EN
Solution
1. Check the device
connections.
2. Run the start-up
sequence.
1. Check the device
connections.
2. Run the start-up
sequence.
1. Check
the device
connections.
2. Run the start-up
sequence.
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.
1. Check that the
water tap is turned
on.
2. Check that there
is water in the
system.
3. Check that
the filter at the
entrance to the
inlet valve is not
blocked.
not
1. Check that the
outlet path is clear.
2. Check that the
steam pipe is not
obstructed, bent or
is not siphoning.
3. Clean the outlet
valve.