JBL AquaCristal UV-C 72W Mode D'emploi Pour L'utilisateur page 125

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
JBL
Parts and designations:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Inserting the UV-C fluorescent bulbs prior to use
Unlock the safety lock on both of the large closing clips (3) by turning 90° counter-clockwise
with a flat screwdriver. Open both large closing clips (3) and remove the electric unit (4) from
the casing. Check the quartz glass inserts (5) in the casing for damage. Remove the safety
clamps (6) from the two fittings for the two UV-C fluorescent bulbs by pressing the lateral
mounts of the base simultaneously and pulling them off. Take the two UV-C fluorescent
4
72W + 110W
Service instructions for the specialist
Casing
Pedestal (2 pcs.)
Closing clips with safety lock
Electric unit incl. power cable and plug
Quartz glass insert
Safety clamp for UV-C fluorescent bulbs
UV-C fluorescent bulbs (2 x 36 W; 2 x 55 W)
Casing seal (2 x)
Profile seal between the electric unit and the quartz glass retaining plate
Stepped hose tail 1, 1 ¼" incl. O-ring (2 pcs. ea.)
Stepped hose tail 1, ½, 2" incl. O-ring ( 2 pcs. ea.)
O-ring for stepped hose tails (2 pcs.)
Flat seal for hose tails
O-ring for stepped hose tails (2 pcs.)
Inspection window for checking fluorescent bulb function
Cover for the inspection window for checking fluorescent bulb function (2 pcs.)
Turbo bypass switch
Inspection window for checking the flow of water with an impeller
Cover for the impeller inspection window incl. O-ring
Screws for the quartz glass retaining plate with nuts (M4x18 cross recessed hexagon head)
Quartz glass retaining plate
O-ring for quartz glass inserts (2 pcs.)
O-ring for the inspection window for checking fluorescent bulb function and impeller (3 pcs.)
Impeller incl. axle and rubber bushings
UV-C Water Clarifier

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquacristal uv-c 110w

Table des Matières