Select the desired receiver mode using the switch [17]:
Position
0
receiver deactivated
Position
chime mode activated
Position
alarm mode activated
Chime mode (switch [17 on position
]
When a signal from the activated transmitter is received then the
receiver reacts according to the position of the switch [21]:
Position
2x loud chime sound, light flashes 15 seconds
Position
2x quiet chime sound, light flashes 15 seconds
Position
no sound, light flashes 15 seconds
Alarm mode (swtch [17 on position
]
When a signal from the activated transmitter is received
the 60 second exit delay
, then the receiver rects according to the position
of the switch [21]:
Position 0
immediate alarm sound and flashing light for 30
seconds
Position 15
1x beep sound
after 15 seconds entry delay
alarm sound and flashing light for 30 seconds
Position 30
1x beep sound
after 30 seconds entry delay
alarm sound and flashing light for 30 seconds
!
After selection of the alarm mode
connecting the receiver to the mains outlet when the alarm mode is
preselected the 60 second exit delay commences. During this time the
area of detection can be crossed without without causing an alarm.
!
If the switch [17] is set at position 15 or 30 then a beep sound will be
heard upon detection. There follows an entry delay of 15 or 30 seconds
during which time the receiver can be removed from the mains outlet
before the alarm sounds.
!
During the entry delay and during the alarm sound the alarm can only be
stopped by removing the receiver from the mains outlet.
!
After every chime or alarm sound there follows a reset period of approx. 4
seconds after which time the selected mode is reactivated.
GB - 24
Detection from an external contact (EXT)
Requirements:
!
!
!
)
Each time an external contact is closed or opened a signal will be transmitted.
After each change of state there is a reset period of approx. 4 seconds.
Changing the batteries
If the LED [4] lights red the batteries must be replaced.
!
)
after the end of
!
!
Maintenance + cleaning
!
!
using switch [17] or after
Declaration of conformity
The company Indexa GmbH hereby declares that the wireless chime FD 01
conforms with the basic requirements and the other relevant regulations of
the EU Council Directive 1999/5/EC. The conformity has been documented.
The complete declaration of conformity can be read at: www.pentatech.de.
an external contact is connected to the EXT connection cable [16]
the EXT connection cable [16] is connected to the EXT socket [8]
the switch [17] set to position EXT or PIR
Press on the arrow marking on the battery compartment cover [13] and
push this downwards (in the direction of the arrow). Remove the three
visible batteries. Remove the battery at the back of the compartment by
pulling the cloth tab [12].
Place 4 new AA batteries in the battery compartment [10]. Pay attention
to the polarity; the negative (-) pole of each battery must connect to a
spring contact [11].
Replace the battery compartment cover.
Check the proper condition and function regularly.
Use a soft, dry cloth to clean the surfaces of the appliance.
0678