Installation with external air supply
1. Attach the hose to the external air connector using a hose
clip (
Do not t a hose clip onto the Jøtul F 483 pedestal
with a rotating set as this prevents the set from rotating).
Make sure the hose is long enough so that joints
are not necessary. The external air hose insulation ends
approx. 10 cm below the burn chamber.
2. Re t any parts that have been removed from the product.
4.3 Chimney and ue pipe
The replace must only be connected to a chimney and
ue pipe approved for solid fuel replaces with ue gas
temperatures as speci ed in «1.0 Technical Data».
The cross-section of the chimney must be designed to t
the replace. Use «1.0 Technical Data» to calculate the
correct chimney cross-section.
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the replace and the hole in the chimney. See g. 1 for
minimum dimensions.
Make sure that the ue pipe rises all the way up to the
chimney.
With a rear outlet, use a ue pipe bend with a sweep hatch
to allow sweeping.
Please note that it is extremely important for connections
to have a degree of
exibility. This is to prevent any
movement in the installation leading to the formation of
cracks.
For recommended chimney draught, see «1.0 Technical
Data». For ue pipe dimensions with the relevant cross-
section, see "1.0 Technical Data".
NB! The minimum recommended chimney length is 3.5 m
from the ue pipe insert. If the draught is too strong, a ue
pipe damper can be installed and used to reduce the draught.
ENGLISH