Safety rules

The personnel carrying out the installation, commission-
ing, maintenance or repair of the device must be properly
qualified for this type of work. In particular, the persons
concerned must
- be suitably trained and familiar with handling com
pressed-air systems besides being informed about the
associated dangers,
- know the content of the relevant instructions for
installation and operation, and
- prossess vocational qualifications or entitlements in
this particular field of work.
Before the start of any work, the housing must first be
depressurized.
In the case of CLEARPOINT filters with BEKOMAT all the
rules of the separate instructions need to be complied with.
To ensure safe functioning, only use the device within the
operational limits (operating pressure, operating tempera-
ture, volumetric flow, material stability).
Where a BEKOMAT is installed, it must be ensured that
the device is designed for the stated volumetric flow of
compressed air or gas. Condensate surges into the device
can impair the function.
In the event of leaks, shut off the compressed-air supply
immediately and eliminate the cause in order to maintain
safe and cost-effective operation.
CLEARPOINT filters, including accessories, must be
checked once a week. This applies in particular to the
function of the separator.
CLEARPOINT L100 - L304
english

Areas of application

CLEARPOINT filters are designed for the separation of
solid particles, aerosols, oil vapours and odours from non-
aggressive compressed air or industrial gases. Depending on
the specific application, the filter housings are provided with
different inserts:
C
Coarse filter for the separation of coarse solid matter pol-
lutants up to 25 µm.
G
General purpose filter element for the separation of large
dirt particles up to 5 µm.
F
Fine filter element for the separation of liquids up to 0.1
mg/m³ and solid particles up to 1 µm.
S
Super fine filter element for the separation of liquids up to
0.01 mg/m³ and solid particles up to 0.01 µm.
N
Nano filter element for the separation of liquids up to 0,003
mg/m³ and solid particles up to 0,01 µm.
A
Activated carbon filter elements for the sepa- ration of
oil vapours up to 0.003 mg/m³ and odours.
R(x) Dust filter for the separation of solid particles,
fineness from C to N
Max. operating pressure: standard 200 psi
Max. operating temperature:
Recommended operating temperature:
C, G, F, S, N:
A:
R(x):
+35 °F ... +140 °F
+35 °F ... +104 °F
+35 °F ... +86 °F
+35 °F ... +140 °F