Di-soric LHT 9-45 M 10 P3IU-B4 Notice De Montage page 35

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Current output 4...20 mA
Factory setting
I [mA]
20
4
0(ASP)
MEW = final value of the measuring range
In the set measuring range the output signal is between 4 and 20 mA.
Faults are also displayed:
• Too much light or object too close: 3.5 mA for a rising edge (ASP < AEP),
20.5 mA for falling edge (ASP > AEP).
• Object too far or no object present: 20.5 mA for rising edge, 3.5 mA for
falling edge.
Voltage output 0...10 V
Factory setting
U [V]
10
0
0(ASP)
MEW = final value of the measuring range
In the set measuring range the output signal is between 0 and 10 V.
mm
10000(AEP)
mm
10000(AEP)
Measuring range scaled
I [mA]
20
4
0
ASP
AEP
Measuring range scaled
U [V]
10
0
0
ASP
AEP
mm
MEW
mm
MEW