Programming

The sensor is programmed using the two buttons [Mode/Enter] and
[Set].
First call a parameter with [Mode/Enter], select the requested value
with [Set] and confirm it pressing again [Mode/Enter].
* Decrease the value: Let the display move to the maximum setting
1
MODE
SET
ENTER
2
MODE
SET
ENTER
3
MODE
SET
ENTER
Change more parameters:
4
Start again with step 1.
value. Then the cycle starts again at the minimum setting value.
Press [Mode/Enter] until the
requested parameter is displayed.
Press [Set] and keep it pressed.
The indicated current parameter
value flashes for 5 s,
then it is increased*
(incremental by pressing briefly or
scrolling by holding pressed).
Press [Mode/Enter] briefly (=
acknowledgement). The parameter
is displayed again, the new para-
meter value becomes effective.
Finish programming:
Wait for 15 s or press [Mode/
Enter] until the current measured
value is displayed again.