Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7

Commissioning

Carry out a visual inspection before each start-up or re-start. Inspect the following before starting the
system:
Electrical connections
Correct seating, leak tightness and condition of piping and pipe connectors
Correct seating and condition of compressed air connections if pneumatic valves are used
Mechanical components for visible defects (cracks, loose connections etc.)
Fill-level of tank B101, max. 3 litres of water in entire system
Eliminate any damage discovered during inspection before commissioning.
Supply the system with 24 V DC electrical voltage with a mains power supply unit.
8

Technical data

Technical data, system
Max. operating pressure in piping
Power supply for the station
Profile plate
Station height: with one tank
with two tanks
EduKit Basic in cardboard box
outside dimensions
weight
EduKit Advanced components in Systainer V
outside dimensions
weight
Volumetric flow of the pump
Tank for clean water
Flexible piping system
Optional –
if 2-way ball valve is used:
Compressed air supply
operating pressure
© Festo Didactic 746310
50 kPa (0.5 bar)
24 V DC / 4.5 A (max. 100 W)
350 x 200 mm
670 mm
1090 mm
560 x 393 x 280 mm (H x W x D)
9,25 kg
420 x 396 x 296 mm (H x W x D)
6,75 kg
0 to 10 l/min.
Max. 3 litres
DN15 (15 mm dia.)
600 kPa (6 bar)
37