Contents
EU Declaration of conformity
Safety instructions
EU Declaration of conformity
We declare under our sole responsibility that this product corres-
ponds to the directives 2014/35/EU, 2006/42/EC, 2014/30/EU and
2011/65/EU and conforms with the following standards or norma-
tive documents: EN 61010-1, EN 61010-2-010, EN 61010-2-051,
EN 61326-1, EN 60529 and EN ISO 12100.
A copy of the complete EU Declaration of Conformity can be re-
quested at sales@ika.com.
EN
Safety instructions
/// General information
• Read the operating instructions in its entirety before
using the device and follow the safety instructions.
• Keep the operating instructions in a place where it can be ac-
cessed by everyone.
Page
• Ensure that only trained staff work with the device.
• Follow the safety instructions, guidelines, occupational health
17
and safety and accident prevention regulations.
17
• Electrical outlet must be grounded (protective ground contact).
19
• Attention - Magnetism!
19
Effects of the magnetic field have to be taken into account (e.g.
19
data storage media, cardiac pacemakers ...).
20
• Risk of burns!
Exercise caution when touching parts of the housing and the
21
heating plate.
21
The heating plate can reach dangerous temperatures. Pay attention
22
to the residual heat on the heating plate after switching off the stirrer.
23
The device may only be transported when the heating plate has
cooled down.
24
24
/// Device design
24
• Do not use the device in explosive atmospheres, it is not EX-
25
protected.
• With substances capable of forming an explosive mixture, ap-
26
propriate safety measures must be applied, e.g. working under
27
a fume hood.
• To avoid body injury and property damage, observe the relevant
safety and accident prevention measures when processing ha-
zardous materials.
• Set up the device in a spacious area on an even, stable, clean,
non-slip, dry and fireproof surface.
• The feet of the device must be clean and undamaged.
• Ensure that the power cord set / temperature sensor cable does
not touch the heating plate.
• Check the device and accessories for damage before each use.
Do not use damaged components.
/// Permissible medium / contaminants / side reactions
• Only process media that will not react dangerously to the extra
energy produced through processing. This also applies to any ex-